Sufficient MRI graft structural integrity at 9 months after anterior cruciate ligament reconstruction with hamstring tendon autograft

Knee Surg Sports Traumatol Arthrosc. 2022 Jun;30(6):1893-1900. doi: 10.1007/s00167-021-06830-2. Epub 2022 Jan 18.

Abstract

Purpose: To assess the MRI-measured structural integrity of hamstring autograft at 9 months after anterior cruciate ligament reconstruction (ACLR) surgery.

Methods: A prospective cohort study was conducted including 34 patients (mean age 36.8 ± 11.8 years; 73.5% males) who underwent ACLR with hamstring autograft. In addition, 36 patients (mean age 39.2 ± 10.5 years; 69.4% males) without any ACL injury were also reviewed and served as control group. The primary outcome used for examining graft maturity at 9 months after ACLR was the MRI-based signal-to-noise quotient (SNQ) of reconstructed ACL. SNQ values were stratified into 3 different categories: excellent: < 0.1; good: ≥ 0.1 and ≤ 0.19; fair: ≥ 0.2. The KT-1000 knee arthrometer was used to measure the side-to-side difference in the anterior tibial translation between the ACLR knee and the contralateral healthy knee in the ACLR group.

Results: Reconstructed ACLs were found with a mean SNQ of 0.078 ± 0.061, while almost all ACL-reconstructed patients (97%; 33 out of 34) were found with excellent or good SNQ values (< 0.019). The mean KT-1000 in the ACLR group was 0.071 mm ± 0.926 mm, while there were no patients in the ACLR cohort with a KT-1000 value > 3 mm. The mean 9-months MRI-based SNQ of ACLR group was significantly higher compared to the mean MRI-based SNQ of the control group (p < 0.001). Multiple regression analysis showed no correlation between SNQ and age, gender, time from injury to ACLR, graft size, or simultaneous treatment of additional intra-articular knee lesions.

Conclusions: In this cohort of 34 ACL-reconstructed patients, 97% of hamstring tendon autografts demonstrated excellent/good MRI signal intensity and excellent functional results (KT-1000 < 3 mm) at 9 months after surgery. Based on this finding, it is suggested that return to sports after ACLR with hamstring autograft can be considered safe at 9 months post surgery. Furthermore, while structural integrity of the graft has been achieved at this time point, statistical differences found in SNQ values of ACL-reconstructed patients compared to ACLs of healthy individuals highlight the continuing process of graft maturation and remodelling.

Level of evidence: Level III.

Keywords: ACL reconstruction; Graft healing; Hamstring tendon; KT-1000 arthrometer; MRI; Return to sports; Signal-to-noise quotient.

MeSH terms

  • Adult
  • Anterior Cruciate Ligament Injuries* / diagnostic imaging
  • Anterior Cruciate Ligament Injuries* / surgery
  • Anterior Cruciate Ligament Reconstruction* / methods
  • Autografts / surgery
  • Female
  • Hamstring Tendons* / transplantation
  • Humans
  • Knee Joint / surgery
  • Magnetic Resonance Imaging
  • Male
  • Middle Aged
  • Prospective Studies
  • Transplantation, Autologous