Clinical Outcomes Using Freestyle Valve-Valsalva Graft Composite Conduit for Aortic Root Replacement

Ann Thorac Surg. 2022 Sep;114(3):643-649. doi: 10.1016/j.athoracsur.2021.12.022. Epub 2022 Jan 11.

Abstract

Background: We reviewed the clinical outcomes of a novel method of aortic root replacement using a self-constructed tissue valve conduit composed of a Freestyle subcoronary valve sewn into a Valsalva graft.

Methods: From 2005 to 2020, 523 patients had aortic root replacement operations using a self-constructed Freestyle subcoronary-Valsalva graft tissue valve conduit. Median patient age was 62 years (interquartile range [IQR] 54-70), and 430 (82%) were men. Primary outcomes were mortality and the need for reoperation. Multivariable regression analyses were performed to identify risk factors for mortality and reoperation.

Results: Urgent procedures comprised 48.37% of cases, and 29.26% were reoperative procedures. Concomitant ascending aorta replacement, hemiarch replacement, and total arch replacement were required in 348 (67%), 227 (44%), and 40 (8%) patients, respectively. Cardiopulmonary bypass and cross-clamp times were 189 minutes (IQR, 164-218) and 166 minutes (IQR, 145-191), respectively. Early mortality was 7.7% (40), and 5- and 10-year survival rates were 83% and 71%, respectively. At the last echocardiogram follow-up left ventricular ejection fraction, left ventricular end-diastolic diameter, degree of aortic insufficiency, and mean aortic valve gradient were significantly improved from baseline (P < .001). Increasing age, peripheral artery disease, tobacco use, increased preoperative creatinine, and prior aortic valve surgery were risk factors for both mortality and the composite outcome (P < .02).

Conclusions: In a complex patient population aortic root replacement using a self-constructed composite tissue valve conduit comprising a Freestyle subcoronary valve-Valsalva graft can be performed with excellent operative and 10-year outcomes. Midterm survival was acceptable, and valve durability was outstanding with an exceedingly low incidence for valve reintervention.

Publication types

  • Review

MeSH terms

  • Aorta / surgery
  • Aortic Valve / diagnostic imaging
  • Aortic Valve / surgery
  • Bioprosthesis*
  • Female
  • Heart Valve Prosthesis Implantation* / methods
  • Humans
  • Male
  • Middle Aged
  • Postoperative Complications / etiology
  • Reoperation
  • Retrospective Studies
  • Stroke Volume
  • Treatment Outcome
  • Ventricular Function, Left