Tips and Tricks in surgical reduction of the posterior column of AO/OTA C3 pilon fractures

BMC Musculoskelet Disord. 2022 Jan 3;23(1):2. doi: 10.1186/s12891-021-04890-6.

Abstract

Background: Accurate posterior column reduction remains a challenging and controversial topic in the management of complex pilon fractures (AO/OTA C3). We aim to report the outcomes of surgical treatment for 22 AO/OTA C3 pilon fracture cases between January 2015 and May 2017 and highlight some traps and tips.

Methods: Three patients underwent two-stage early plating on the posterior column through a posterolateral approach. The remaining 19 patients were treated with two-stage delayed plating on the posterior column: 11 patients were treated with a posterolateral approach, five patients with a modified posteromedial approach, and three patients with a single anterior approach. The reduction of the posterior column was evaluated according to the Burwell-Charnley's radiographic criteria, and functional outcomes were assessed using the American Orthopedic Foot and Ankle Society (AOFAS) scores.

Results: Posterior column malreduction occurred in five cases, including in one case that was re-adjusted immediately and in another case that was re-adjusted during a two-staged delayed operation. According to Burwell-Charnley's criteria, the satisfactory rate of fracture reduction was 81.8%. After 1 year, the mean AOFAS score was 81.9 (81.9 ± 9.9); the outcome was excellent in three (20.0%), good in nine (60.0%), and fair in three (20.0%). Excellent or good outcomes were noted in 12 patients (80.0%).

Conclusions: The combined anterior and posterior approach is suggested in the second stage of plating so that the posterior column fragments can be re-adjusted intraoperatively, if necessary. Following these procedures, satisfactory reduction and recovery of good ankle function can be anticipated.

Keywords: Die-punch fragment; Pilon fractures; Posterior column reduction; Surgical approach; Treatment outcome.

MeSH terms

  • Ankle Fractures* / diagnostic imaging
  • Ankle Fractures* / surgery
  • Ankle Joint
  • Fracture Fixation, Internal
  • Humans
  • Retrospective Studies
  • Tibial Fractures* / diagnostic imaging
  • Tibial Fractures* / surgery
  • Treatment Outcome