An Exploratory Study on the Relationship between Brachial Arterial Blood Flow and Cardiac Output

J Healthc Eng. 2021 Dec 23:2021:1251199. doi: 10.1155/2021/1251199. eCollection 2021.

Abstract

Background: We have obtained prospective clinical outcomes using the brachial artery largely, such as Korotkoff sound and vasomotor function measurement by ultrasound guidance to predict the prognosis of cardiovascular diseases. Very few reports on the quantitative measurement of the relationship between the brachial artery blood flow and cardiac output have been reported.

Purpose: (1) To investigate whether the quantitative relationship between the brachial artery blood flow and cardiac output existed. (2) To provide a theoretical basis for taking advantage of artificial intelligence (AI) using Korotkoff sound analogously as far as possible to predict the cardiac output.

Methods: A total of 586 patients who underwent cardiac color ultrasound in our center from 2021.3 to 2021.7 were included for analyses. The vascular parameters of the right upper limb brachial artery (such as the Diameter, Area, Blood Velocity, and Flow) were measured immediately after the cardiac color ultrasound, and some basic clinical parameters (Age, Sex, BMI, and Disease) were recorded subsequently. Ultimately, the Mann-Whitney and independent sample T-test were used to analyze the data.

Results: (1) The mean Rate of the brachial arterial blood flow to cardiac output was 1.23%, and the mean 95% CI was (1.18%, 1.29%), indicating that the value was mainly concentrated in the current value interval. The indicator demonstrates that there is no significant difference currently among the patients with hypertension, coronary heart disease, and cardiac dysfunction. (2) The brachial artery wall diameter (Dist) is significantly thicker in patients with coronary heart disease and hypertension compared to patients with other cardiovascular diseases. (3) Cardiac output augments remarkably in patients with hypertension.

Conclusion: Our study suggests that the Rate (brachial artery blood flow/cardiac output) is a constant of 1.23% approximately. It provides a theoretical basis for the subsequent application of the artificial intelligence (AI) method to predict heart function using Korotkoff sound, cope with large computational amounts, and improve computational speed. It is also indirectly proved that hypertension can lead to a change in peripheral vascular hyperplasia and increase cardiac output.

Publication types

  • Research Support, Non-U.S. Gov't
  • Retracted Publication

MeSH terms

  • Artificial Intelligence*
  • Blood Flow Velocity
  • Brachial Artery* / diagnostic imaging
  • Cardiac Output
  • Hemodynamics
  • Humans
  • Prospective Studies