Multicenter prospective study of the efficacy of stereomicroscopic on-site evaluation in endoscopic ultrasound-guided tissue acquisition in patients with pancreatic cancer

Pancreatology. 2022 Mar;22(2):311-316. doi: 10.1016/j.pan.2021.12.011. Epub 2021 Dec 24.

Abstract

Objective: In sample isolation processing by stereomicroscopy (SIPS), a technique used to assess the quality of specimens collected during endoscopic ultrasound (EUS)-guided tissue acquisition (EUS-TA), the cutoff value of stereomicroscopically visible white core (SVWC) (≥11 mm) indicates high diagnostic sensitivity. However, the procedure of SIPS is complicated and time-consuming. Therefore, we devised the stereomicroscopic on-site evaluation (SOSE), a new rapid assessment method that is simpler than SIPS and only determines if the SVWC cutoff value is attained. We aimed to examine the usefulness of SOSE in a multicenter, prospective setting.

Methods: Seventy patients from multiple institutions with solid pancreatic masses suspected to be pancreatic cancer were included. EUS-TA was performed using a 22-gauge Franseen needle. SVWCs were measured on-site using stereomicroscopy. The primary outcome was the sensitivity of SVWC cutoff value in EUS-TA with SOSE.

Results: The total number of punctures was 214 and SOSE was performed on 150 punctures. The SVWC cutoff value collection rate was 100% per lesion, with 80% in the first pass, 79% in the second pass, and 78% per puncture in all passes. The median time taken to determine the SVWC cutoff value for SOSE was 47 s. The sensitivity of the SVWC cutoff value was 93.2% for histology and 96.6% for cytology + histology. The per-lesion accuracy of pathological diagnosis reached the highest level (98.6%) at the second puncture.

Conclusions: SOSE showed high diagnostic sensitivity and may be a new rapid assessment method for the diagnosis of malignant pancreatic cancer using EUS-TA.

Keywords: Diagnostic techniques; Endoscopic ultrasound-guided fine needle aspiration; Endoscopy; Endosonography; Stereomicroscopy.

Publication types

  • Multicenter Study

MeSH terms

  • Endoscopic Ultrasound-Guided Fine Needle Aspiration* / methods
  • Endosonography / methods
  • Humans
  • Needles
  • Pancreatic Neoplasms* / diagnostic imaging
  • Pancreatic Neoplasms* / pathology
  • Prospective Studies