Introduction: Revisions due to the fracture of ceramic-on-ceramic (CoC) bearing are rare, however when they occur, they represent a major challenge to an orthopedic surgeon for ensuring safe and long-term survival of the replaced bearing.
Case report: We present a case of fractured ceramic liner of total hip prosthesis that underwent revision to a metal-on-polyethylene (MoP) bearing couple, with consequent huge periprosthetic metallosis. Shortly after, the second revision operation followed using the third bearing couple of ceramic-on-polyethylene (CoP). At 10 years follow-up after the operation due to ceramic fracture, the patient is now pain free with full range of motion of the revised hip.
Conclusion: Establishment of diagnostic routes and recommended protocols for CoC bearing fracture would allow easier recognition of potential fracture and diminish its consequences for the patients.
Keywords: Ceramic Bearing Fracture; Revision Hip Arthroplasty; Tribology.
Copyright: © Indian Orthopaedic Research Group.