Novel Digital Measurement Technique to Analyze the Palatine Suture Expansion after Palatine Rapid Maxillary Expansion Technique

J Pers Med. 2021 Sep 27;11(10):962. doi: 10.3390/jpm11100962.

Abstract

The aim of the study was to validate a novel digital measurement method to quantify the volume of the midpalatal suture after rapid maxillary expansion (RME).

Material and methods: Eight patients with maxillary skeletal transverse deficiency were submitted to palatine suture expansion using the McNamara orthodontic appliance during a period of nine months. After 30 days of treatment, all patients were exposed postoperatively to a cone-beam computed tomography (CBCT) scan. Afterwards, the scans were uploaded into the three-dimensional orthodontic-planning software to allow the volumetric assessment of the palatine suture expansion through palatine rapid maxillary expansion using a McNamara appliance. The repeatability was analyzed by repeating twice the measures by a single operator and reproducibility was analyzed by repeating three times the measures by two operators, and Gage R&R statistical analysis was performed.

Results: The expansion of the midpalatal suture by means of the rapid maxillary expansion technique, in terms of digital volume measurement, showed a repeatability value of 0.09% and between the two operators a reproducibility value of 0.00% was shown.

Conclusions: The novel measurement technique demonstrated a high repeatability and reproducibility rate for volume assessment of the palatine suture expansion through palatine rapid maxillary expansion technique.

Keywords: McNamara appliance; digital dentistry; orthodontics; palatine suture expansion; rapid maxillary expansion.