Optimization of Advanced Live-Cell Imaging through Red/Near-Infrared Dye Labeling and Fluorescence Lifetime-Based Strategies

Int J Mol Sci. 2021 Oct 14;22(20):11092. doi: 10.3390/ijms222011092.

Abstract

Fluorescence microscopy is essential for a detailed understanding of cellular processes; however, live-cell preservation during imaging is a matter of debate. In this study, we proposed a guide to optimize advanced light microscopy approaches by reducing light exposure through fluorescence lifetime (τ) exploitation of red/near-infrared dyes. Firstly, we characterized key instrumental elements which revealed that red/near-infrared laser lines with an 86x (Numerical Aperture (NA) = 1.2, water immersion) objective allowed high transmission of fluorescence signals, low irradiance and super-resolution. As a combination of two technologies, i.e., vacuum tubes (e.g., photomultiplier) and semiconductor microelectronics (e.g., avalanche photodiode), type S, X and R of hybrid detectors (HyD-S, HyD-X and HyD-R) were particularly adapted for red/near-infrared photon counting and τ separation. Secondly, we tested and compared lifetime-based imaging including coarse τ separation for confocal microscopy, fitting and phasor plot analysis for fluorescence lifetime microscopy (FLIM), and lifetimes weighting for enhanced stimulated emission depletion (STED) nanoscopy, in light of red/near-infrared multiplexing. Mainly, we showed that the choice of appropriate imaging approach may depend on fluorochrome number, together with their spectral/lifetime characteristics and STED compatibility. Photon-counting mode and sensitivity of HyDs together with phasor plot analysis of fluorescence lifetimes enabled the flexible and fast imaging of multi-labeled living H28 cells. Therefore, a combination of red/near-infrared dyes labeling with lifetime-based strategies offers new perspectives for live-cell imaging by enhancing sample preservation through acquisition time and light exposure reduction.

Keywords: FLIM; FLIM-STED; STED; confocal; fluorescence lifetime; live-cell imaging; sample preservation; τ separation.

MeSH terms

  • Cell Line, Tumor
  • Equipment Design
  • Fluorescein / chemistry
  • Fluorescence
  • Fluorescent Dyes / chemistry
  • Humans
  • Image Processing, Computer-Assisted / methods*
  • Infrared Rays
  • Microscopy, Confocal / instrumentation
  • Microscopy, Confocal / methods*
  • Microscopy, Fluorescence / instrumentation*
  • Microscopy, Fluorescence / methods*
  • Photons
  • Rhodamines / chemistry

Substances

  • Fluorescent Dyes
  • Rhodamines
  • rhodamine B
  • Fluorescein