Performance Analysis of a Full-Scale Desalination Plant with Reverse Osmosis Membranes for Irrigation

Membranes (Basel). 2021 Oct 11;11(10):774. doi: 10.3390/membranes11100774.

Abstract

Reverse osmosis (RO) is the most widely used technology for seawater desalination purposes. The long-term operating data of full-scale plants is key to analyse their performance under real conditions. The studied seawater reverse osmosis (SWRO) desalination plant had a production capacity of 5000 m3/d for irrigation purposes. The operating data such as conductivities flows, and pressures were collected for around 27,000 h for 4 years. The plant had sand and cartridge filters without chemical dosing in the pre-treatment stage, a RO system with one stage, 56 pressure vessels, seven RO membrane elements per pressure vessel and a Pelton turbine as energy recovery device. The operating data allowed to calculate the average water and salt permeability coefficients (A and B) of the membrane as well as the specific energy consumption (SEC) along the operating period. The calculation of the average A in long-term operation allowed to fit the parameters of three different models used to predict the mentioned parameter. The results showed a 30% decrease of A, parameter B increase around 70%. The SEC was between 3.75 and 4.25 kWh/m3. The three models fitted quite well to the experimental data with standard deviations between 0.0011 and 0.0015.

Keywords: desalination; long-term; operating data; reverse osmosis membranes; seawater.