The TRUTH confirmed: validation of an intraindividual comparison of gadobutrol and gadoteridol for imaging of glioblastoma using quantitative enhancement analysis

Eur Radiol Exp. 2021 Oct 12;5(1):46. doi: 10.1186/s41747-021-00240-2.

Abstract

Background: Previous intraindividual comparative studies evaluating gadobutrol and gadoteridol for contrast-enhanced magnetic resonance imaging (MRI) of brain tumours have relied on subjective image assessment, potentially leading to misleading conclusions. We used artificial intelligence algorithms to objectively compare the enhancement achieved with these contrast agents in glioblastoma patients.

Methods: Twenty-seven patients from a prior study who received identical doses of 0.1 mmol/kg gadobutrol and gadoteridol (with appropriate washout in between) were evaluated. Quantitative enhancement (QE) maps of the normalised enhancement of voxels, derived from computations based on the comparison of contrast-enhanced T1-weighted images relative to the harmonised intensity on unenhanced T1-weighted images, were compared. Bland-Altman analysis, linear regression analysis and Pearson correlation coefficient (r) determination were performed to compare net QE and per-region of interest (per-ROI) average QE (net QE divided by the number of voxels).

Results: No significant differences were observed for comparisons performed on net QE (mean difference -24.37 ± 620.8, p = 0.840, r = 0.989) or per-ROI average QE (0.0043 ± 0.0218, p = 0.313, r = 0.958). Bland-Altman analysis revealed better per-ROI average QE for gadoteridol-enhanced MRI in 19/27 (70.4%) patients although the mean difference (0.0043) was close to zero indicating high concordance and the absence of fixed bias.

Conclusions: The enhancement of glioblastoma achieved with gadoteridol and gadobutrol at 0.1 mmol/kg bodyweight is similar indicating that these agents have similar contrast efficacy and can be used interchangeably, confirming the results of a prior double-blind, randomised, intraindividual, crossover study.

Keywords: Contrast media; Crossover studies; Gadobutrol; Gadoteridol; Glioblastoma.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Artificial Intelligence
  • Contrast Media
  • Cross-Over Studies
  • Gadolinium
  • Glioblastoma* / diagnostic imaging
  • Heterocyclic Compounds
  • Humans
  • Organometallic Compounds*

Substances

  • Contrast Media
  • Heterocyclic Compounds
  • Organometallic Compounds
  • gadoteridol
  • gadobutrol
  • Gadolinium