The predictive value of microperfusion assessments for the follow-up of tibial bypass grafts

J Vasc Surg. 2022 Mar;75(3):1008-1013. doi: 10.1016/j.jvs.2021.08.100. Epub 2021 Sep 30.

Abstract

Objective: We conducted a prospective evaluation of microperfusion parameters after tibial bypass surgery was performed. Differences between grafts with occlusions during follow-up and patent grafts were analyzed in relation to the pedal arch quality.

Methods: Patients receiving tibial bypass grafts for chronic limb-threatening ischemia from 2019 to 2020 were included. Assessment of microcirculation (parameters: hemoglobin oxygen saturation [sO2] and flow) was done by laser Doppler flowmetry and white light spectrometry (oxygen-to-see), supine and in elevation, whereas the macrocirculation was evaluated by the ankle-brachial index and duplex ultrasound examination. The quality of run-off was graded for each patient. Measurements were performed preoperatively, 1 day postoperatively, and after 6 months. Patients with graft occlusions during follow-up (OCCLUDED) and patients without occlusions (OPEN) were compared.

Results: We included 42 patients (13 women, 29 men; mean age, 76.1 years; range, 60-89 years) were included. The patency of all grafts 1 day after the operation was confirmed by ultrasound examination. The overall analysis of the microcirculation showed significant changes in both the supine and elevated leg position between measurements taken preoperatively, 1 day after the operation, and after 6 months for the parameters sO2 and FLOW (sO2 supine, P = .001; sO2 elevated, P < .001; FLOW supine, P < .001; FLOW elevated, P < .001). The comparison of the values 1 day after the operation yielded significantly decreased microperfusion parameters (both O2 and FLOW) in the group that developed bypass occlusion in the later follow-up period (sO2 supine: OCCLUDED, 35.7% [7.3-65.0] and OPEN, 48.7% [25.0-72.3] P = .011; FLOW supine: OCCLUDED, 27.7 A.U. [12.7-52.7] and OPEN, 57.3 A.U. [16.0-106.7], P = .008). No significant differences in the severity of the arch impairment was found between the OPEN and OCCLUDED groups (P = .651). Absolute values of the parameters sO2 and flow showed no correlation with the pedal arch classification.

Conclusions: Significantly poorer microperfusion was detected postoperatively in patients with later occurrence of graft occlusions despite patent grafts on the first postoperative day. Microperfusion measurements might be a possible tool for the prediction of graft failure.

Keywords: Bypass surgery; Chronic limb-threating ischemia; Graft occlusion; Microperfusion; O2C.

Publication types

  • Comparative Study
  • Observational Study

MeSH terms

  • Aged
  • Aged, 80 and over
  • Ankle Brachial Index
  • Blood Flow Velocity
  • Blood Vessel Prosthesis Implantation* / adverse effects
  • Diagnostic Techniques, Cardiovascular*
  • Female
  • Graft Occlusion, Vascular / diagnosis*
  • Graft Occlusion, Vascular / etiology
  • Graft Occlusion, Vascular / physiopathology
  • Humans
  • Laser-Doppler Flowmetry
  • Male
  • Microcirculation*
  • Middle Aged
  • Peripheral Arterial Disease / diagnosis
  • Peripheral Arterial Disease / physiopathology
  • Peripheral Arterial Disease / surgery*
  • Predictive Value of Tests
  • Prospective Studies
  • Risk Assessment
  • Risk Factors
  • Spectrum Analysis
  • Tibial Arteries / diagnostic imaging
  • Tibial Arteries / physiopathology
  • Tibial Arteries / surgery*
  • Time Factors
  • Treatment Outcome
  • Ultrasonography, Doppler, Duplex
  • Vascular Patency*