Association between anion gap and mortality of aortic aneurysm in intensive care unit after open surgery

BMC Cardiovasc Disord. 2021 Sep 23;21(1):458. doi: 10.1186/s12872-021-02263-4.

Abstract

Background: There has not been a well-accepted prognostic model to predict the mortality of aortic aneurysm patients in intensive care unit after open surgery repair. Otherwise, our previous study found that anion gap was a prognosis factor for aortic aneurysm patients. Therefore, we wanted to investigate the relationship between anion gap and mortality of aortic aneurysm patients in intensive care unit after open surgery repair.

Methods: From Medical Information Mart for Intensive Care III, data of aortic aneurysm patients in intensive care unit after open surgery were enrolled. The primary clinical outcome was defined as death in intensive care unit. Univariate analysis was conducted to compare the baseline data in different groups stratified by clinical outcome or by anion gap level. Restricted cubic spline was drawn to find out the association between anion gap level and mortality. Subgroup analysis was then conducted to show the association in different level and was presented as frost plot. Multivariate regression models were built based on anion gap and were adjusted by admission information, severity score, complication, operation and laboratory indicators. Receiver operating characteristic curves were drawn to compare the prognosis ability of anion gap and simplified acute physiology score II. Decision curve analysis was finally conducted to indicate the net benefit of the models.

Results: A total of 405 aortic aneurysm patients were enrolled in this study and the in-intensive-care-unit (in-ICU) mortality was 6.9%. Univariate analysis showed that elevated anion gap was associated with high mortality (P value < 0.001), and restricted cubic spline analysis showed the positive correlation between anion gap and mortality. Receiver operating characteristic curve showed that the mortality predictive ability of anion gap approached that of simplified acute physiology score II and even performed better in predicting in-hospital mortality (P value < 0.05). Moreover, models based on anion gap showed that 1 mEq/L increase of anion gap improved up to 42.3% (95% confidence interval 28.5-59.8%) risk of death.

Conclusions: The level of serum anion gap was an important prognosis factor for aortic aneurysm mortality in intensive care unit after open surgery.

Keywords: Anion gap; Aortic aneurysm; Intensive care unit; Open surgery; Prognosis.

Publication types

  • Observational Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Acid-Base Equilibrium*
  • Acid-Base Imbalance / diagnosis
  • Acid-Base Imbalance / etiology
  • Acid-Base Imbalance / mortality*
  • Acid-Base Imbalance / physiopathology
  • Aortic Aneurysm / diagnostic imaging
  • Aortic Aneurysm / mortality
  • Aortic Aneurysm / surgery*
  • Databases, Factual
  • Hospital Mortality*
  • Humans
  • Intensive Care Units
  • Risk Assessment
  • Risk Factors
  • Time Factors
  • Treatment Outcome
  • Vascular Surgical Procedures / adverse effects
  • Vascular Surgical Procedures / mortality*