Transurethral catheterization of female domestic pigs with a Foley catheter

Lab Anim. 2022 Apr;56(2):196-199. doi: 10.1177/00236772211041480. Epub 2021 Sep 9.

Abstract

This report describes transurethral catheterization with a Foley catheter in 19 anaesthetized, laterally recumbent female pigs with a chest circumference of 72.1 ± 4.2 cm and weighing approximately 40 kg. Catheterization within five minutes was successful in 78.9% of the pigs. Catheterization depth, measured as the distance between the bladder neck and the mucocutaneous junction of the vulva, was 14.5 ± 1.3 cm and correlated with chest circumference but not body length. Measurement of catheterization depth aids in optimal positioning and may prevent inflation of the Foley catheter in the urethra.

Keywords: Foley catheter; Swine; transurethral catheterization.

MeSH terms

  • Animals
  • Catheters
  • Female
  • Sus scrofa*
  • Swine
  • Urethra
  • Urinary Bladder
  • Urinary Catheterization*