The autoclaving and re-implantation of an infected prosthesis as a spacer during resection knee arthroplasty: a systematic review

Musculoskelet Surg. 2022 Jun;106(2):111-125. doi: 10.1007/s12306-021-00722-x. Epub 2021 Jul 28.

Abstract

Background: Hofmann et al., in 1995, first described an articulating spacer made by cleaning and autoclaving the original femoral component, which is then re-implanted with a new tibial polyethylene. This systematic review aims to assess the state of existing evidence on the intraoperative autoclaving and re-use of an infected prosthesis, as a spacer, during a two-stage revision following Periprosthetic Joint Infections (PJI).

Methods: A systematic review was conducted with methods described in the Preferred Reporting Items for Systematic Reviews and Meta-Analyses. OVID-MEDLINE®, EMBASE, Cochrane Library, SCOPUS, Web of Science, Google Scholar and PubMed were searched from 1995 to April 2020 to identify relevant studies.

Results: Fourteen studies were included in this systematic review: two prospective case series; six retrospective comparative studies and six retrospective case series. The reviewed studies included 567 patients (571 knees): 394 patients treated with autoclaved components and 173 with a spacer made of new components. The cumulative re-infection rate in patients treated with re-used autoclaved components was 13.7% (54 re-infections in 394 patients), whereas in control patients the re-infection rate was 13.3% (23 re-infections in 173 patients). The final Range of Movement in patients treated using the autoclaved components as a spacer, compared with patients receiving static spacers, was significantly higher in three out of four comparative studies.

Conclusion: There is a moderate level of evidence that the intraoperative autoclaving and re-use of an infected prosthesis as a spacer, during a knee resection arthroplasty, is an effective procedure in the management of knee PJI.

Keywords: Autoclaving; Knee osteoarthritis; Periprosthetic joint infection; Re-use; Total knee replacement; Two-stage revision strategy.

Publication types

  • Review
  • Systematic Review

MeSH terms

  • Anti-Bacterial Agents / therapeutic use
  • Arthroplasty, Replacement, Knee* / methods
  • Humans
  • Knee Prosthesis* / adverse effects
  • Prosthesis-Related Infections* / etiology
  • Prosthesis-Related Infections* / surgery
  • Reinfection
  • Reoperation / methods
  • Retrospective Studies
  • Treatment Outcome

Substances

  • Anti-Bacterial Agents