Abstract

Attenuation correction remains a challenge in pelvic PET/MRI. In addition to the segmentation/model-based approaches, deep learning methods have shown promise in synthesizing accurate pelvic attenuation maps (μ-maps). However, these methods often misclassify air pockets in the digestive tract, potentially introducing bias in the reconstructed PET images. The aims of this work were to develop deep learning-based methods to automatically segment air pockets and generate pseudo-CT images from CAIPIRINHA-accelerated MR Dixon images. Methods: A convolutional neural network (CNN) was trained to segment air pockets using 3-dimensional CAIPIRINHA-accelerated MR Dixon datasets from 35 subjects and was evaluated against semiautomated segmentations. A separate CNN was trained to synthesize pseudo-CT μ-maps from the Dixon images. Its accuracy was evaluated by comparing the deep learning-, model-, and CT-based μ-maps using data from 30 of the subjects. Finally, the impact of different μ-maps and air pocket segmentation methods on the PET quantification was investigated. Results: Air pockets segmented using the CNN agreed well with semiautomated segmentations, with a mean Dice similarity coefficient of 0.75. The volumetric similarity score between 2 segmentations was 0.85 ± 0.14. The mean absolute relative changes with respect to the CT-based μ-maps were 2.6% and 5.1% in the whole pelvis for the deep learning-based and model-based μ-maps, respectively. The average relative change between PET images reconstructed with deep learning-based and CT-based μ-maps was 2.6%. Conclusion: We developed a deep learning-based method to automatically segment air pockets from CAIPIRINHA-accelerated Dixon images, with accuracy comparable to that of semiautomatic segmentations. The μ-maps synthesized using a deep learning-based method from CAIPIRINHA-accelerated Dixon images were more accurate than those generated with the model-based approach available on integrated PET/MRI scanners.

Keywords: PET quantification; PET/MRI; attenuation correction; deep learning; pseudo-CT.

Publication types

  • Research Support, N.I.H., Extramural

MeSH terms

  • Deep Learning*
  • Humans
  • Image Processing, Computer-Assisted / methods
  • Magnetic Resonance Imaging / methods
  • Pelvis / diagnostic imaging
  • Positron-Emission Tomography / methods
  • Tomography, X-Ray Computed