Pre-procedural high-pitch coronary CT angiography assessment of patients undergoing transcatheter aortic valve implantation (TAVI) without patient-specific adjustment: analysis of diagnostic performance

Clin Radiol. 2021 Nov;76(11):862.e29-862.e36. doi: 10.1016/j.crad.2021.06.008. Epub 2021 Jul 11.

Abstract

Aim: To evaluate the ability to assess the coronary arteries using pre-procedural computed tomography (CT; high-pitch mode) in patients referred for transcatheter aortic valve implantation (TAVI).

Methods and materials: CT and invasive coronary angiography (ICA) were performed pre-TAVI in 100 patients (46 women; 79 ± 5.9 years). CT was performed in prospectively ECG-triggered high-pitch mode after intravenous administration of 70 ml iodinated contrast medium. Image quality was assessed using a four-point scale (graded 0-3). Significant coronary artery stenosis (≥50% diameter) was graded as either present or absent by one observer and in one-third of patients by two observers independently. ICA was the standard of reference. Results were reported per segment and per patient.

Results: Twenty-two percent of patients had known coronary artery disease (CAD). In two cases, a coronary anomaly was detected. Diagnostic image quality (grade 1-3) was achieved in 30.3% of segments. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were 75%, 80.5%, 16%, and 98.5%, respectively. Significant coronary stenosis could be ruled out completely in all segments in three patients. The interrater agreement per patient was excellent (kappa = 1).

Conclusion: Relevant coronary findings can frequently be observed in high-pitch TAVI-planning CT. Despite the limitations of the technique and in patients referred to pre-TAVI evaluation (rapid heart rate, coronary calcifications, etc.), a valid evaluation of coronary arteries is possible in a considerable proportion of segments with a high NPV; however, few studies were completely free of motion artefacts to dependably exclude CAD using this technique in this challenging group of patients.

MeSH terms

  • Aged
  • Aortic Valve / diagnostic imaging
  • Aortic Valve / surgery
  • Aortic Valve Stenosis / diagnostic imaging*
  • Aortic Valve Stenosis / surgery*
  • Computed Tomography Angiography / methods*
  • Contrast Media
  • Coronary Angiography / methods*
  • Electrocardiography
  • Female
  • Humans
  • Male
  • Radiographic Image Enhancement / methods
  • Reproducibility of Results
  • Sensitivity and Specificity
  • Transcatheter Aortic Valve Replacement*

Substances

  • Contrast Media