Comparison of a Single Versus Double Perclose Technique for Percutaneous Transfemoral Transcatheter Aortic Valve Replacement

J Invasive Cardiol. 2021 Jul;33(7):E540-E548.

Abstract

Background: The optimal strategy for arterial closure in percutaneous transfemoral transcatheter aortic valve replacement (TF-TAVR) remains under debate.

Methods: Single-center, prospective, observational study of consecutive patients undergoing TF-TAVR between March 2018 and December 2019 who underwent closure with an upfront single vs double Perclose device. Device success, access-site vascular, and bleeding complications were defined according to the Valvular Academic Research Consortium (VARC)-2 criteria. Inverse-probability of treatment weighting (IPTW) was used to balance baseline characteristics between groups.

Results: A total of 241 patients (mean age, 81.4 ± 8.5 years, 47% women) were included, of which 127 underwent an upfront single-Perclose (SP) strategy and 114 underwent an upfront double-Perclose (DP) strategy. Fifty-six percent of patients were treated with a CoreValve (Medtronic). The SP group was less likely to be on dialysis and on aspirin, but were more likely to receive a CoreValve, with larger valve sizes and larger delivery sheaths. Baseline characteristics were well balanced after IPTW adjustment. Device success rate was comparable between groups (96% in the SP group vs 93% in the DP group; P=.39). The SP technique was associated with fewer vascular complications (8.7% in the SP group vs 26.3% in the DP group; P<.01; IPTW relative risk [RR], 0.34; 95% confidence Interval [CI], 0.16-0.71) and bleeding complications (2.4% in the SP group vs 12.3% in the DP group; P<.01; IPTW RR, 0.21; 95% CI, 0.06-0.76) compared with the DP technique. There were no differences in 30-day mortality.

Conclusion: An upfront SP technique is equally efficacious and not associated with increased vascular and bleeding complications compared with an upfront DP technique in patients undergoing percutaneous TF-TAVR.

Keywords: Perclose; large-bore access; transcatheter aortic valve replacement.

Publication types

  • Observational Study

MeSH terms

  • Aged
  • Aged, 80 and over
  • Aortic Valve / diagnostic imaging
  • Aortic Valve / surgery
  • Aortic Valve Stenosis* / diagnosis
  • Aortic Valve Stenosis* / surgery
  • Female
  • Femoral Artery / surgery
  • Humans
  • Male
  • Prospective Studies
  • Risk Factors
  • Transcatheter Aortic Valve Replacement* / adverse effects
  • Treatment Outcome