A Magnetic Resonance Imaging Index to Predict Crohn's Disease Postoperative Recurrence: The MONITOR Index

Clin Gastroenterol Hepatol. 2022 May;20(5):e1040-e1049. doi: 10.1016/j.cgh.2021.06.035. Epub 2021 Jun 30.

Abstract

Background & aims: We developed and validated a magnetic resonance imaging-based index to predict Crohn's disease (CD) postoperative recurrence (POR).

Methods: Patients with CD who underwent a postoperative evaluation for recurrence (with colonoscopy and MRI no longer than 105 days apart) were included between 2006 and 2016 in University Hospital of Nancy, France. MRI items with good levels of intra-rater and inter-rater agreement (Gwet's coefficient ≥0.5) were selected. The MRI in Crohn's Disease to Predict Postoperative Recurrence (MONITOR) index's performance was assessed in terms of the area under the receiver operating characteristic curve (AUROC) and accuracy, by considering the Rutgeerts score as the gold standard. The MONITOR index was validated with a bootstrap method and an independent cohort.

Results: Seventy-three MRI datasets were interpreted by 2 radiologists. Seven items (bowel wall thickness, contrast enhancement, T2 signal increase, diffusion-weighted signal increase, edema, ulcers, and the length of the diseased segment) had a Gwet's coefficient ≥0.5 and were significantly associated with the Rutgeerts score, leading to their inclusion in the MONITOR index. All the items had a weighting of 1, except the "ulcers" item weighting 2.5, reflecting the higher adjusted odds ratio. The AUROC [95% confidence interval] for the prediction of endoscopic POR (Rutgeerts score >i1) was 0.80 [0.70-0.90]. The optimal threshold was a MONITOR index ≥1, giving a sensitivity of 79%, a specificity of 55%, a predictive positive value of 68%, and a predictive negative value of 68%. The bootstrap validation gave an AUROC of 0.85 [0.73-0.97]. In the validation cohort, a MONITOR index ≥1 gave a sensitivity of 87%, a specificity of 75%, a predictive positive value of 84.6%, and a predictive negative value of 75%.

Conclusions: The MONITOR index is an efficient, reliable, easy-to-apply tool that can be used in clinical practice to predict the POR of CD.

Keywords: Crohn’s Disease; Inflammatory Bowel Disease; Magnetic Resonance Imaging; Postoperative Recurrence; Radiology; Surgery.

MeSH terms

  • Colonoscopy
  • Crohn Disease* / diagnostic imaging
  • Crohn Disease* / pathology
  • Crohn Disease* / surgery
  • Humans
  • Magnetic Resonance Imaging
  • Postoperative Period
  • Recurrence
  • Severity of Illness Index
  • Ulcer