Evaluation of HEAR score to rule-out major adverse cardiac events without troponin test in patients presenting to the emergency department with chest pain

Eur J Emerg Med. 2021 Aug 1;28(4):292-298. doi: 10.1097/MEJ.0000000000000791.

Abstract

Background and importance: Current guidelines for patients presenting to the emergency department with chest pain without ST-segment elevation myocardial infarction (non-STEMI) on electrocardiogram are based on troponin measurement. The HEART score is reportedly a reliable work-up strategy that combines clinical evaluation with troponin value. A clinical rule that could select very low-risk patients without the need for a blood test (HEAR score, being the HEART score without the troponin item) would be of great interest.

Objectives: To prospectively assess the safety of a HEAR score <2 to rule-out non-STEMI without troponin measurement. Secondary objective was to assess the safety of a sequential strategy that combines HEAR score and HEART (defined as two-step HEART strategy).

Design, settings and participants: Prospective observational study in six emergency departments. Patients with nontraumatic chest pain and no alternative diagnosis were included and followed up for 45 day. Patients were considered at low-risk if the HEAR score was <2 or, for the two-step HEART strategy, if the HEART score was <4.

Outcomes measure and analysis: The primary endpoint was the 45-day rate of major adverse cardiac events (MACE) in patients with a HEAR score <2. A HEAR score based strategy was consider safe if the rate of the primary endpoint was below 1%, with an upper margin of the 95% confidence interval (CI) below 3%.

Results: Among 1452 patients included, 1402 were analyzed and 97 (7%) had a MACE during the follow-up period. The HEAR score was <2 in 279 (20%) patients and one presented a MACE [0.4% (95% CI: 0.01-1.98)]. The two-step HEART strategy classified low-risk an additional 476 patients (34%) and one of these 476 patients had a MACE [0.3% (95% CI: 0.03-0.95)]. The two-step HEART strategy would have theoretically avoided 360 troponin measurements (19%).

Conclusions: In our prospective multicenter study, a HEAR based work-up strategy was safe, with a very low risk of MACE at 45 day. We also report that a two-step HEART-based strategy may safely allow significant reduction of troponin measurements in patients presenting to the emergency department with chest pain.

Trial registration: ClinicalTrials.gov NCT02813499.

Publication types

  • Multicenter Study
  • Observational Study

MeSH terms

  • Biomarkers
  • Chest Pain* / diagnosis
  • Chest Pain* / etiology
  • Electrocardiography
  • Emergency Service, Hospital
  • Humans
  • Prospective Studies
  • Risk Assessment
  • Risk Factors
  • Troponin*

Substances

  • Biomarkers
  • Troponin

Associated data

  • ClinicalTrials.gov/NCT02813499