Discordance Between Respiratory Drive and Sedation Depth in Critically Ill Patients Receiving Mechanical Ventilation

Crit Care Med. 2021 Dec 1;49(12):2090-2101. doi: 10.1097/CCM.0000000000005113.

Abstract

Objectives: In mechanically ventilated patients, deep sedation is often assumed to induce "respirolysis," that is, lyse spontaneous respiratory effort, whereas light sedation is often assumed to preserve spontaneous effort. This study was conducted to determine validity of these common assumptions, evaluating the association of respiratory drive with sedation depth and ventilator-free days in acute respiratory failure.

Design: Prospective cohort study.

Setting: Patients were enrolled during 2 month-long periods in 2016-2017 from five ICUs representing medical, surgical, and cardiac specialties at a U.S. academic hospital.

Patients: Eligible patients were critically ill adults receiving invasive ventilation initiated no more than 36 hours before enrollment. Patients with neuromuscular disease compromising respiratory function or expiratory flow limitation were excluded.

Interventions: Respiratory drive was measured via P0.1, the change in airway pressure during a 0.1-second airway occlusion at initiation of patient inspiratory effort, every 12 ± 3 hours for 3 days. Sedation depth was evaluated via the Richmond Agitation-Sedation Scale. Analyses evaluated the association of P0.1 with Richmond Agitation-Sedation Scale (primary outcome) and ventilator-free days.

Measurements and main results: Fifty-six patients undergoing 197 bedside evaluations across five ICUs were included. P0.1 ranged between 0 and 13.3 cm H2O (median [interquartile range], 0.1 cm H2O [0.0-1.3 cm H2O]). P0.1 was not significantly correlated with the Richmond Agitation-Sedation Scale (RSpearman, 0.02; 95% CI, -0.12 to 0.16; p = 0.80). Considering P0.1 terciles (range less than 0.2, 0.2-1.0, and greater than 1.0 cm H2O), patients in the middle tercile had significantly more ventilator-free days than the lowest tercile (incidence rate ratio, 0.78; 95% CI, 0.65-0.93; p < 0.01) or highest tercile (incidence rate ratio, 0.58; 95% CI, 0.48-0.70; p < 0.01).

Conclusions: Sedation depth is not a reliable marker of respiratory drive during critical illness. Respiratory drive can be low, moderate, or high across the range of routinely targeted sedation depth.

MeSH terms

  • Adult
  • Aged
  • Cohort Studies
  • Critical Illness / therapy
  • Female
  • Humans
  • Hypnotics and Sedatives / adverse effects
  • Hypnotics and Sedatives / classification*
  • Male
  • Middle Aged
  • Ontario
  • Prospective Studies
  • Respiration, Artificial / methods
  • Respiration, Artificial / statistics & numerical data
  • Respiratory Mechanics / drug effects*
  • Respiratory Mechanics / physiology
  • Retrospective Studies

Substances

  • Hypnotics and Sedatives