Towards personalised medicine in autoimmune hepatitis: Measurement of thiopurine metabolites results in higher biochemical response rates

J Hepatol. 2021 Aug;75(2):324-332. doi: 10.1016/j.jhep.2021.03.023. Epub 2021 Apr 16.

Abstract

Background & aims: Patients with autoimmune hepatitis (AIH) usually receive maintenance therapy with thiopurines, such as azathioprine (AZA) or mercaptopurine. Genetic polymorphisms in AZA metabolism can lead to variations in thioguanine nucleotide (TGN) and 6-methylmercaptopurine, both of which can cause adverse drug reactions (ADRs). In inflammatory bowel disease, a therapeutic TGN range (225-450 pmol/8x108 erythrocytes) has been identified to optimise effectiveness. We evaluated the benefits of a personalised medicine approach to thiopurine dosing, in comparison to standard weight-based dosing.

Methods: A retrospective matched cohort study of 214 patients with AIH who were seen at King's College between 1999-2019 was performed. Metabolite levels were measured in 109 patients. The control group included 105 patients on weight-based thiopurine dosing with no metabolite monitoring.

Results: Biochemical response (BR) occurred more frequently at 6-month follow-up in patients with metabolite monitoring compared to those on a weight-based regimen (77% vs. 60%, p = 0.008). This remained true with data analysis based on clinicians who measure metabolites and those who do not (BR at 6 months: 84% vs. 64%, p = 0.016). Patients with BR had TGN levels within the therapeutic range of 225-450 pmol/8x108 erythrocytes significantly more often than those who failed to achieve or lost BR (40% vs. 13%, p <0.0001). Moreover, TGN levels within the pre-defined therapeutic range predicted more stable disease within 6 months of testing compared to levels outside the range (p <0.0001). A high proportion of patients with sub-therapeutic TGN levels (75-225 pmol/8x108 erythrocytes) remained in BR (75% vs. 81%, p = 0.589) with fewer ADRs (44% vs. 86%, p = 0.0002) when compared to patients with therapeutic TGN levels.

Conclusion: A strategy of personalised medicine using metabolite levels can optimise treatment regimens in AIH, resulting in fewer ADRs whilst maintaining BR.

Lay summary: This study looked to see if measuring the breakdown products of a medication used in autoimmune hepatitis increases the chances of gaining good control of the disease, when compared to a group of patients who were on a dose of this medication based on their weight. A group of 214 patients with autoimmune hepatitis were split into 2 groups: roughly half had their medication dose adjusted according to measurements of breakdown products in the blood, whilst the other half received their weight-based dose as normal. The results confirmed that using a personalised approach and checking drug breakdown products resulted in fewer side effects and potentially improved control of disease.

Keywords: autoimmune hepatitis; azathioprine; outcomes; thioguanine; thiopurine metabolites.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adult
  • Cohort Studies
  • Drug Monitoring / methods
  • Drug Monitoring / statistics & numerical data
  • Female
  • Hepatitis, Autoimmune / drug therapy*
  • Hepatitis, Autoimmune / physiopathology
  • Humans
  • Male
  • Methyltransferases / analysis*
  • Methyltransferases / blood
  • Methyltransferases / metabolism*
  • Middle Aged
  • Ontario
  • Precision Medicine / methods
  • Retrospective Studies

Substances

  • Methyltransferases
  • thiopurine methyltransferase