Background: This study explored the comparison of the thermal insulation effect of incubator to infusion thermometer in laparoscopic hysterectomy.
Methods: We assigned 75 patients enrolled in the study randomly to three groups: Group A: Used warming blanket; group B: Used warming blanket and infusion thermometer; group C: Used warming blanket and incubator. The nasopharyngeal temperature at different time points during the operation served as the primary outcome.
Results: The nasopharyngeal temperature of the infusion heating group was significantly higher than that of the incubator group 60 min from the beginning of surgery (T3): 36.10 ± 0.20 vs 35.81 ± 0.20 (P<0.001)90 min from the beginning of surgery (T4): 36.35 ± 0.20 vs 35.85 ± 0.17 (P<0.001). Besides, the nasopharyngeal temperature of the incubator group was significantly higher compared to that of the control group 60 min from the beginning of surgery (T3): 35.81 ± 0.20 vs 35.62 ± 0.18 (P<0.001); 90 min from the beginning of surgery (T4): 35.85 ± 0.17 vs 35.60 ± 0.17 (P<0.001). Regarding the wake-up time, that of the control group was significantly higher compared to the infusion heating group: 24 ± 4 vs 21 ± 4 (P = 0.004) and the incubator group: 24 ± 4 vs 22 ± 4 (P = 0.035).
Conclusion: Warming blanket (38 °C) combined infusion thermometer (37 °C) provides better perioperative thermal insulation. Hospitals without an infusion thermometer can opt for an incubator as a substitute.
Trial registration: This trial was registered with ChiCTR2000039162 , 20 October 2020.
Keywords: Incubator; Infusion thermometer; Laparoscopic; Nasopharyngeal temperature; Warming blanket.