Neonatal eye screening for 203 healthy term new-borns using a wide-field digital retinal imaging system

BMC Ophthalmol. 2021 Mar 9;21(1):128. doi: 10.1186/s12886-021-01882-x.

Abstract

Background: The current practice for new-born eye examination by an Ophthalmologist in Malaysian hospitals is limited to only preterm new-borns, syndromic or ill infants. Healthy term new-borns are usually discharged without a thorough eye examination. This study is aimed at determining the proportion and types of ocular abnormalities detected in purportedly healthy term new-borns.

Method: This cross-sectional study is comprised of 203 participants, all purportedly healthy term new-born infants from the Obstetrics and Gynaecology ward at Hospital Kuala Lumpur over a 6 months period. The examination list includes external eye examination, red reflex test, and fundus imaging using a wide-field digital retinal imaging system (Phoenix Clinical ICON Paediatric Retinal Camera) by a trained Investigator. The pathologies detected were documented. The results were compared and correlated with similar studies published in the literature previously.

Results: Total ocular abnormalities were detected in 34% of the infants. The most common finding was retinal haemorrhage in 29.6% of the infants, of which 53.3% occurred bilaterally. Spontaneous vaginal delivery (SVD) remained the greatest risk factor which has nearly 3.5 times higher risk of new-borns developing retinal haemorrhage compared to Lower Segment Caesarean Section (LSCS). There was a 6% increased likelihood of developing retinal haemorrhage for every 1-min increment in the duration of 2nd stage of labour.

Conclusion: Universal eye screening for all new-borns using a wide-field digital imaging system is realistically possible, safe, and useful in detecting posterior segment disorders. The most common abnormality detected is retinal haemorrhage.

Keywords: Eye screening; Haemorrhage; Healthy; New-born; Term; Universal.

MeSH terms

  • Cesarean Section*
  • Child
  • Cross-Sectional Studies
  • Female
  • Fundus Oculi
  • Humans
  • Infant
  • Infant, Newborn
  • Neonatal Screening*
  • Pregnancy
  • Retina