Feasibility of Imaging-Based 3-Dimensional Models to Design Patient-Specific Osteosynthesis Plates and Drilling Guides

JAMA Netw Open. 2021 Feb 1;4(2):e2037519. doi: 10.1001/jamanetworkopen.2020.37519.

Abstract

Importance: In acetabular fracture surgery, achieving an optimal reconstruction of the articular surface decreases the risk of osteoarthritis and the subsequent need for total hip arthroplasty. However, no one-size-fits-all osteosynthesis plate is available owing to differences in fracture patterns and variations in pelvic anatomy. Currently, osteosynthesis plates need to be manually contoured intraoperatively, often resulting in inadequate reduction and fixation of the fractured segments.

Objective: To determine the feasibility and accuracy of a novel concept of fast-track 3-dimensional (3-D) virtual surgical planning and patient-specific osteosynthesis for complex acetabular fracture surgery.

Design, setting, and participants: This case series study examines the use of patient-specific osteosynthesis plates for patients needing operative treatment for displaced associated-type acetabular fractures at a tertiary university-affiliated referral center and level 1 trauma center between January 1, 2017, and December 31, 2018. Models were created in 3-D based on computed tomography (CT) data, fractures were virtually reduced, and implant positions were discussed in a multidisciplinary team of clinicians and engineers. Patient-specific osteosynthesis plates with drilling guides were designed, produced, sterilized and clinically applied within 4 days. Data were analyzed at the 1-year follow-up.

Exposures: Development and clinical implementation of personalized fracture surgery.

Main outcomes and measures: The primary outcome was the quality of the reduction as determined by the postoperative CT scan. The secondary outcomes were accuracy of the screw placement and clinical outcome using patient-reported outcome measures.

Results: Ten patients with a median (range) age of 63 (46-79) years with an acetabular fracture were included. The median (interquartile range [IQR]) preoperative gap was 20 (15-22) mm, and the median (IQR) step-off was 5 (3-11) mm. Postoperatively, the median (IQR) gap was reduced to 3 (2-5) mm (P = .005), and the median (IQR) step-off was reduced to 0 (0-2) mm (P = .01), indicating good fracture reduction, indicating good fracture reduction. The mean difference between the preoperative and postoperative gap was 14.6 (95% CI, 10-19) mm, and the mean difference in step-off was 5.7 (95% CI, 2-9) mm. The median (IQR) difference in screw direction between the planning and actual surgery was only 7.1° (7°-8°). All patients retained their native hip and reported good physical functioning at follow-up.

Conclusions and relevance: These findings suggest that 3-D virtual surgical planning, manufacturing, and clinical application of patient-specific osteosynthesis plates and drilling guides was feasible and yielded good clinical outcomes. Fast-track personalized surgical treatment could open a new era for the treatment of complex injuries.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Acetabulum / diagnostic imaging
  • Acetabulum / injuries*
  • Aged
  • Bone Plates*
  • Feasibility Studies
  • Female
  • Fracture Fixation, Internal / instrumentation*
  • Fracture Fixation, Internal / methods*
  • Fractures, Bone / diagnostic imaging
  • Fractures, Bone / surgery*
  • Humans
  • Imaging, Three-Dimensional
  • Male
  • Manufacturing Industry
  • Middle Aged
  • Models, Anatomic
  • Patient Reported Outcome Measures
  • Printing, Three-Dimensional
  • Tomography, X-Ray Computed
  • Treatment Outcome