Electrochemical Impedance Spectroscopy Biosensor Enabling Kinetic Monitoring of Fucosyltransferase Activity

ACS Sens. 2021 Mar 26;6(3):1003-1011. doi: 10.1021/acssensors.0c02206. Epub 2021 Feb 17.

Abstract

Monitoring glycosyltransferases on biosensors is of great interest for pathogen and cancer diagnostics. As a proof of concept, we here demonstrate the layer-by-layer immobilization of a multivalent neoglycoprotein (NGP) as a substrate for a bacterial fucosyltransferase (FucT) and the subsequent binding of the fucose-specific Aleuria aurantia lectin (AAL) on an electrochemical impedance spectroscopy (EIS) sensor. We report for the first time the binding kinetics of a glycosyltransferase in real-time. Highly stable EIS measurements are obtained by the modification of counter and reference electrodes with polypyrrole: polystyrene sulfonate (PPy:PSS). In detail, the N-acetyllactosamine (LacNAc)-carrying NGP was covalently immobilized on the gold working electrode and served as a substrate for the FucT-catalyzed reaction. The LacNAc epitopes were converted to Lewisx (Lex) and detected by AAL. AAL binding to the Lex epitope was further confirmed in a lectin displacement and a competitive lectin binding inhibition experiment. We monitored the individual kinetic processes via EIS. The time constant for covalent immobilization of the NGP was 653 s. The FucT kinetics was the slowest process with a time constant of 1121 s. In contrast, a short time constant of 11.8 s was determined for the interaction of AAL with the modified NGPs. When this process was competed by 400 mM fucose, the binding was significantly slowed down, as indicated by a time constant of 978 s. The kinetics for the displacement of bound AAL by free fucose was observed with a time constant of 424 s. We conclude that this novel EIS biosensor and the applied workflow has the potential to detect FucT and other GT activities in general and further monitor protein-glycan interactions, which may be useful for the detection of pathogenic bacteria and cancer cells in future biomedical applications.

Keywords: biosensor; electrical impedance spectroscopy; fucosyltransferase; lectin; neoglycoprotein.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Ascomycota
  • Biosensing Techniques*
  • Dielectric Spectroscopy*
  • Fucosyltransferases / metabolism
  • Kinetics
  • Polymers
  • Pyrroles

Substances

  • Polymers
  • Pyrroles
  • Fucosyltransferases

Supplementary concepts

  • Aleuria aurantia