Removal of a Knotted Pulmonary Artery Catheter Using a Percutaneous Tracheostomy Set

J Cardiothorac Vasc Anesth. 2022 Apr;36(4):1123-1126. doi: 10.1053/j.jvca.2021.01.021. Epub 2021 Jan 16.

Abstract

Placement of a pulmonary artery catheter is not a risk-free technique. Related incidents include ventricular arrhythmias, air embolisms, pulmonary artery perforation, infections, or catheter thrombosis. Herein the authors report a rare complication-the intracardiac knotting and its successful extraction using a percutaneous tracheostomy set in a hemodynamically compromised patient after a heart transplant.

Keywords: Swan-Ganz; catheterization; heart transplantation; pulmonary artery.

Publication types

  • Case Reports

MeSH terms

  • Catheterization, Swan-Ganz / adverse effects
  • Catheters / adverse effects
  • Heart
  • Humans
  • Pulmonary Artery* / diagnostic imaging
  • Pulmonary Artery* / surgery
  • Tracheostomy* / adverse effects