Percutaneous Sonazoid-enhanced ultrasonography combined with in vitro verification for detection and characterization of sentinel lymph nodes in early breast cancer

Eur Radiol. 2021 Aug;31(8):5894-5901. doi: 10.1007/s00330-020-07639-2. Epub 2021 Jan 27.

Abstract

Objectives: To assess the efficacy of percutaneous Sonazoid-enhanced ultrasound and in vitro verification for identification sentinel lymph nodes (SLNs) and diagnosis of metastatic SLNs in patients with early breast cancer (BC).

Methods: Sixty-eight patients with early BC were enrolled finally. After the induction of general anesthesia, 0.4 ml of Sonazoid (SNZ), a new second-generation tissue-specific ultrasound contrast agent (UCA), mixed with 0.6 ml of methylene blue, was injected intradermally. The lymphatic vessels and connected SLNs were immediately observed and marked. After being resected, these SLNs were soaked in saline water and examined still in the mode of contrast-enhanced ultrasound (CEUS) in vitro. This procedure could ensure that all the enhanced nodes had been removed as much as possible. The numbers of SLNs detected by UCA and blue dye were recorded. The enhancement patterns of SLNs were compared with the final pathological results.

Results: SLNs detection rate by SNZ-CEUS was 100%, which was higher than that by blue dye (95.59%). CEUS identified a median of 1.5 nodes, while blue dye identified a median of 1.9 nodes per case (p = 0.0012). When homogeneous high perfusion and complete annular high perfusion were regarded as negative nodes, the sensitivity and negative predictive value were 92.31% and 96.79% respectively, while the specificity was 84.21%.

Conclusions: Percutaneous SNZ-enhanced ultrasonography combined with in vitro verification is a feasible and reliable method for SLNs identification intraoperatively. Enhancement patterns can be helpful in determining the status of SLNs.

Key points: • CEUS with percutaneous injection of Sonazoid can successfully identify SLNs with the rate of 100% in early breast cancer patients, higher than 95.59% of blue dye. • Sonazoid, with high affinity with reticuloendothelial cells, increases the imaging time of SLNs and facilitates biopsy intraoperatively better than Sonovue as a lymphatic tracer. • Homogenous high and complete annular high perfusions have a sensitivity of 92.31% and a negative predictive value of 96.79% in the prediction of uninvolved SLNs.

Keywords: Breast neoplasms; Contrast media; Sentinel lymph node; Sonazoid; Ultrasonography.

MeSH terms

  • Breast Neoplasms* / diagnostic imaging
  • Breast Neoplasms* / surgery
  • Female
  • Ferric Compounds
  • Humans
  • Iron
  • Lymph Nodes / diagnostic imaging
  • Oxides
  • Sentinel Lymph Node Biopsy
  • Sentinel Lymph Node* / diagnostic imaging
  • Ultrasonography

Substances

  • Ferric Compounds
  • Oxides
  • Sonazoid
  • Iron