Scepter dual-lumen balloon catheter for Onyx embolization for dural arteriovenous fistula

BMC Neurol. 2021 Jan 20;21(1):31. doi: 10.1186/s12883-021-02046-6.

Abstract

Background: This study aimed to evaluate the efficacy and safety of Scepter dual-lumen balloon catheter for transarterial Onyx embolization of dural arteriovenous fistula (DAVF).

Methods: Transarterial Onyx embolization using a Scepter dual-lumen balloon catheter (Scepter-assisted Onyx embolization) for DAVF was attempted in a total of 35 patients (mean age, 52.5 years; M:F = 24:11) between October 2012 and December 2018. The results of Scepter-assisted Onyx embolization were evaluated with respect to total procedural and Onyx injection times, the types and number of feeders requiring embolization, angiographic and clinical outcomes, and treatment-related complications.

Results: Initial presentations were non-hemorrhagic neurological deficits in 10, intracranial hemorrhage in 8, seizure in 7, headache in 7, and intractable tinnitus in 3. All DAVF were aggressive type (Borden type 2, 14.3 %; type 3, 85.7 %). Scepter-assisted Onyx embolization resulted in immediately complete occlusion in 33 patients (94.3 %) and near complete occlusion in 2 patients. Middle meningeal artery (51.4 %) was the most commonly used for Scepter-assisted technique, followed by occipital artery (42.9 %), ascending pharyngeal artery (2.9 %) and superficial temporal artery (2.9 %). There was no difference in complete occlusion rate between middle meningeal artery and the other arteries (94.4 % versus 94.1 %). The median number of total feeders embolized was 1 (range, 1-3). The median total procedural time was 45 minutes (range, 21 minutes - 127 minutes) and the median Onyx injection time was 11 minutes (range, 3 minutes - 25 minutes). All patients recovered completely (n = 31) or partially (n = 4) from presenting symptoms. Treatment-related complications occurred in 2 patients, of whom one had a permanent morbidity (2.8 %, ipsilateral facial nerve palsy). No patient showed a recurrence on follow-up imaging (median, 15 months; range, 3-56 months).

Conclusions: Scepter-assisted transarterial Onyx embolization showed a very high complete occlusion rate with a low morbidity and no recurrence in aggressive type DAVF. Scepter dual-lumen balloon catheter seems to be a useful tool for transarterial Onyx embolization of DAVF.

Keywords: Dual‐lumen balloon catheter; Dural arteriovenous fistula; Onyx embolization.

MeSH terms

  • Adult
  • Catheters*
  • Central Nervous System Vascular Malformations / therapy*
  • Dimethyl Sulfoxide
  • Embolization, Therapeutic / instrumentation*
  • Embolization, Therapeutic / methods
  • Female
  • Humans
  • Male
  • Middle Aged
  • Polyvinyls
  • Retrospective Studies
  • Treatment Outcome

Substances

  • Onyx copolymer
  • Polyvinyls
  • Dimethyl Sulfoxide