Solid-Contact Potentiometric Sensors Based on Main-Tailored Bio-Mimics for Trace Detection of Harmine Hallucinogen in Urine Specimens

Molecules. 2021 Jan 10;26(2):324. doi: 10.3390/molecules26020324.

Abstract

All-solid-state potentiometric sensors have attracted great attention over other types of potentiometric sensors due to their outstanding properties such as enhanced portability, simplicity of handling, affordability and flexibility. Herein, a novel solid-contact ion-selective electrode (SC-ISE) based on poly(3,4-ethylenedioxythiophene) (PEDOT) as the ion-to-electron transducer was designed and characterized for rapid detection of harmine. The harmine-sensing membrane was based on the use of synthesized imprinted bio-mimics as a selective material for this recognition. The imprinted receptors were synthesized using acrylamide (AA) and ethylene glycol dimethacrylate (EGDMA) as functional monomer and cross-linker, respectively. The polymerization process was carried out at 70 °C in the presence of dibenzoyl peroxide (DBO) as an initiator. The sensing membrane in addition to the solid-contact layer was applied to a glassy-carbon disc as an electronic conductor. All performance characteristics of the presented electrode in terms of linearity, detection limit, pH range, response time and selectivity were evaluated. The sensor revealed a wide linearity over the range 2.0 × 10-7-1.0 × 10-2 M, with a detection limit of 0.02 µg/mL and a sensitivity slope of 59.2 ± 0.8 mV/hamine concentration decade. A 40 mM Britton-Robinson (BR) buffer solution at pH of 6 was used for all harmine measurements. The electrode showed good selectivity towards harmine over other common interfering ions, and maintained a stable electrochemical response over two weeks. After applying the validation requirements, the proposed method revealed good performance characteristics. Method precision, accuracy, bias, trueness, repeatability, reproducibility, and uncertainty were also evaluated. These analytical capabilities support the fast and direct assessment of harmine in different urine specimens. The analytical results were compared with the standard liquid chromatographic method. The results obtained demonstrated that PEDOT/PSS was a promising solid-contact ion-to-electron transducer material in the development of harmine-ISE. The electrodes manifested enhanced stability and low cost, which provides a wide number of potential applications for pharmaceutical and forensic analysis.

Keywords: hallucinogen; harmine; imprinted polymers; ion-selective membrane sensors; poly(3,4-ethylenedioxythiophene) (PEDOT); solid-contact.

MeSH terms

  • Biomimetic Materials / chemistry*
  • Biosensing Techniques*
  • Bridged Bicyclo Compounds, Heterocyclic / chemistry
  • Hallucinogens* / analysis
  • Hallucinogens* / urine
  • Harmine* / analysis
  • Harmine* / urine
  • Humans
  • Methacrylates / chemistry
  • Polymers / chemistry
  • Potentiometry

Substances

  • Bridged Bicyclo Compounds, Heterocyclic
  • Hallucinogens
  • Methacrylates
  • Polymers
  • poly(3,4-ethylene dioxythiophene)
  • Harmine
  • ethylene dimethacrylate