A randomized noninferiority trial comparing the diagnostic yield of the 25G ProCore needle to the standard 25G needle in suspicious pancreatic lesions

Endosc Ultrasound. 2021 Jan-Feb;10(1):57-61. doi: 10.4103/eus.eus_69_20.

Abstract

Background and objectives: The aim of the study was to perform the first randomized trial comparing the diagnostic yield, bloodiness, and cellularity of the 25G standard needle (25S) and the 25G ProCore™ needle (25P).

Materials and methods: All patients referred to the tertiary care referral center for EUS guided fine-needle aspiration (EUS-FNA) of suspicious solid pancreatic lesions were eligible. EUS-FNA was performed in each lesion with both 25S and 25P needles (the choice of the first needle was randomized), using a multipass sampling pattern, without stylet or suction. Rapid on-site evaluation was used when possible. Pap-stained slides were read by a single experienced cytopathologist, blinded to the needle type.

Results: One hundred and forty-three patients were recruited. Samples were positive for cancer in 122/143 (85.3%) with the 25S needle versus 126/143 (88.1%) with the 25P needle, negative in 17/143 (11.9%) with the 25S needle versus 13/143 (9.1%) with the 25P needle, and suspicious in 4/143 (2.8%) with each needle. There was no difference in any outcome based on the type of the first needle. No carryover effect was detected (P = 0.214; NS). Cumulative logistic regression analyses showed no associations between the type of needle and diagnostic yield for cancer, cellularity, or bloodiness. The difference in the yield for cancer was 2.9% (-4.2; 10.1%); with the confidence interval upper within the predetermined noninferiority margin of 15%.

Conclusion: The 25S needle is noninferior to the 25P needle for diagnosing cancer in suspicious pancreatic lesions.

Keywords: 25G ProCore™; EUS-guided fine needle aspiration; mass; pancreas.