Objective: To compare baseline physical and cognitive performance, neurophysiological, and magnetic resonance imaging (MRI) outcomes and examinetheir interrelationship inparticipants with Multiple Sclerosis (MS), already established aseither responder or non-responder to Fampridine treatment, andto examine associationswiththe expanded disability status scale (EDSS) and 12-item MS walking scale (MSWS-12).
Methods: Baseline data from an explorative longitudinal observational study were analyzed. Participants underwent the Timed 25-Foot Walk Test (T25FW), Six Spot Step Test (SSST), Nine-Hole Peg Test, Five Times Sit-to-Stand Test, Symbol Digit Modalities Test (SDMT), neurophysiological testing, including central motor conduction time (CMCT), peripheral motor conduction time (PMCT), motor evoked potential (MEP) amplitudesand electroneuronographyof the lower extremities, and brain MRI (brain volume, number and volume of T2-weighted lesions and lesion load normalized to brain volume).
Results: 41 responders and 8 non-responders were examined. There were no intergroup differences inphysical performance, cognitive, neurophysiological, andMRI outcomes (p > 0.05).CMCT was associated withT25FW, SSST, EDSS, and MSWS-12,(p < 0.05). SDMT was associated with the number and volume of T2-weighted lesions, and lesion load normalized to brain volume (p < 0.05).
Conclusion: No differences were identified between responders and non-responders to Fampridine treatment regarding physical and cognitive performance, neurophysiological or MRI outcomes. The results call for cautious interpretation and further large-scale studies are needed to expand ourunderstanding of underlying mechanisms discriminating Fampridine responders and non-responders.CMCT may be used as a marker of disability and walking impairment, while SDMT was associated with white matter lesions estimated by MRI. ClinicalTrials.gov identifier: NCT03401307.
Keywords: Central nervous system; Magnetic resonance imaging; Multiple sclerosis; Neurophysiology; Peripheral nervous system; Physical performance test.