Flow Virometry Quantification of Host Proteins on the Surface of HIV-1 Pseudovirus Particles

Viruses. 2020 Nov 12;12(11):1296. doi: 10.3390/v12111296.

Abstract

The HIV-1 glycoprotein spike (gp120) is typically the first viral antigen that cells encounter before initiating immune responses, and is often the sole target in vaccine designs. Thus, characterizing the presence of cellular antigens on the surfaces of HIV particles may help identify new antiviral targets or impact targeting of gp120. Despite the importance of characterizing proteins on the virion surface, current techniques available for this purpose do not support high-throughput analysis of viruses, and typically only offer a semi-quantitative assessment of virus-associated proteins. Traditional bulk techniques often assess averages of viral preparations, which may mask subtle but important differences in viral subsets. On the other hand, microscopy techniques, which provide detail on individual virions, are difficult to use in a high-throughput manner and have low levels of sensitivity for antigen detection. Flow cytometry is a technique that traditionally has been used for rapid, high-sensitivity characterization of single cells, with limited use in detecting viruses, since the small size of viral particles hinders their detection. Herein, we report the detection and surface antigen characterization of HIV-1 pseudovirus particles by light scattering and fluorescence with flow cytometry, termed flow virometry for its specific application to viruses. We quantified three cellular proteins (integrin α4β7, CD14, and CD162/PSGL-1) in the viral envelope by directly staining virion-containing cell supernatants without the requirement of additional processing steps to distinguish virus particles or specific virus purification techniques. We also show that two antigens can be simultaneously detected on the surface of individual HIV virions, probing for the tetraspanin marker, CD81, in addition to α4β7, CD14, and CD162/PSGL-1. This study demonstrates new advances in calibrated flow virometry as a tool to provide sensitive, high-throughput characterization of the viral envelope in a more efficient, quantitative manner than previously reported techniques.

Keywords: CD14; CD162 (PSGL-1); CD81 (tetraspanin); calibrated flow virometry; flow cytometry; human immunodeficiency virus (HIV); integrin α4β7; molecules of equivalent soluble fluorophore (MESF); virion-incorporated proteins.

Publication types

  • Research Support, N.I.H., Extramural
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Biomarkers
  • Flow Cytometry* / methods
  • Genetic Engineering*
  • HIV-1 / genetics
  • HIV-1 / metabolism*
  • Host-Pathogen Interactions*
  • Humans
  • Reproducibility of Results
  • Viral Load* / methods
  • Virion* / genetics
  • Virion* / metabolism

Substances

  • Biomarkers