A Clinical Trial of Photobiomodulation Effect on Orthodontic Microscrews Stability Using a 635 nm Red Laser Light

Photobiomodul Photomed Laser Surg. 2020 Oct;38(10):607-613. doi: 10.1089/photob.2020.4863.

Abstract

Background: One of the procedures enhancing implants stability can be photobiomodulation. Objective: To assess the effect of a 635 nm wavelength on orthodontic microscrews stability, survival rate, and an individual patient's pain score. Materials and methods: The study was done with 15 subjects, 30 orthodontic microscrews with a length of 10 mm and diameter 1.4 mm. Implants inserted on the right and left side of the maxilla. The implants in the test group (G1) were irradiated with the laser at palatal and buccal part of peri-implant area (two points). The diode laser (SmartM PRO; Lasotronix, Warsaw, Poland) was used with the following settings: power: 100 mW, spot size: 0.5 cm2, mean power density (irradiance): 200 mW/cm2, in continuous wave (CW) mode, energy per point: 4 J, radiant exposure: 8 J/cm2, time per point: 40 sec, the total energy dose (radiant energy) per session: 8 J in contact mode, handpiece diameter: 8 mm. Laser sessions: day of surgery and 3, 6, 9, 12, 15, 30 days later. Cumulative radiant energy was 59 J. Periotest appliance was used to assess the microscrews stability at day of surgery and 3, 6, 9, 12, 15, 30, 60 days later. Each patient received a survey for individual pain assessment (NRS-11) promptly after the implantation. Results: The analysis after 60 days revealed significantly higher secondary stability for the laser-irradiated microscrews group in comparison with control implants (G2 group) (p = 0.0037). We observed significantly higher stability in the experimental group compared with the control after 30 days (p = 0.0218). Moreover, we noted significantly higher microimplants stability for the control group in comparison with the test group, 9 days after implantation (p = 0.0374). Laser application had no effect on pain reduction noted in the first day in comparison with the control sites (p = 0.6690). No microscrews were lost in the study. Conclusions: Application of a 635 nm laser on peri-implant soft tissue increased the microscrews stability after 30 and 60 days.

Keywords: LLLT; anchorage; implants; mini-implants; orthodontic treatment.

Publication types

  • Clinical Trial

MeSH terms

  • Humans
  • Lasers, Semiconductor* / therapeutic use
  • Pain Measurement
  • Pain* / etiology