Fatigue behavior of subchondral bone under simulated physiological loads of equine athletic training

J Mech Behav Biomed Mater. 2020 Oct:110:103920. doi: 10.1016/j.jmbbm.2020.103920. Epub 2020 Jun 16.

Abstract

Fatigue-induced subchondral bone (SCB) injuries are prevalent among athletes due to the repetitive application of high magnitude loads on joints during intense physical training. Existing fatigue studies on bone utilize a standard fatigue test approach by applying loads of a constant magnitude and frequency even though physiological/realistic loading is a combination of various load magnitudes and frequencies. Metal materials in implant and aerospace applications have been studied for fatigue behavior under physiological or realistic loading, however, no such study has been conducted on biological materials like bones. In this study, we investigated fatigue behavior of SCB under the range of loads likely to occur during a fast-workout of an equine athlete in training. A loading protocol was developed by simulating physiological loads occurring during a fast-workout of a racehorse in training, which consisted of a sequence of compression-compression load cycles, including a warm-up (32, 54, 61 MPa) and cool-down (61, 54, 32 MPa) before and after the slow/fast/slow gallop phase of training, also referred to as a training loop. This loading protocol/training loop was applied at room temperature in load-control mode to cylindrical SCB specimens (n = 12) harvested from third metacarpal medial condyles (MCIII) of twelve thoroughbred racehorses and repeated until fatigue failure. The mean ± standard deviation for total time-to-failure (TTF) was 76,393 ± 64,243 s (equivalent to 18.3 ± 15.7 training workouts) for n = 12 specimens. We observed the highest relative energy loss (REL, hysteresis loss normalized to energy absorbed in a load cycle) under loads equivalent to gallop speeds and all specimens failed under these gallop loads. This demonstrates the importance of the gallop speeds in the development of SCB injury, consistent with observations made in live racehorses. Moreover, specimens with higher mean REL and lower mean stiffness during the first loop had a shorter fatigue life which further confirms the detrimental effect of high energy loss in SCB. Further studies are required to reconcile our results with fatigue injuries among equine athletes and understand the influence of different training programs on the fatigue behavior of subchondral bone.

Keywords: Fatigue life; Loading sequence; MCIII Subchondral bone; Physiological loads; Relative energy loss; Stiffness.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Animals
  • Horses
  • Materials Testing
  • Metacarpal Bones*
  • Physical Conditioning, Animal*
  • Pressure
  • Sports*