A novel Q-value-based nomogram for single intracorneal ring segment implantation versus standard manufacturer's nomogram combined with accelerated cross-linking for treatment of keratoconus: a randomized controlled trial

Acta Ophthalmol. 2021 Jun;99(4):e501-e511. doi: 10.1111/aos.14611. Epub 2020 Sep 15.

Abstract

Purpose: To compare the efficacy of implanting a single Keraring segment according to a novel Q-value-based nomogram (QN) to that of segment implantation according to the manufacturer's standard nomogram (SN), for keratoconus treatment.

Methods: This was a prospective, randomized controlled trial of 104 patients (104 eyes) with Amsler-Krumeich grade 1 or 2 keratoconus, and type 1 or 2 cone asymmetry determined according to manufacturer's classification. They were randomly distributed into two groups: group A patients (n = 52) underwent Keraring implantation according to the SN, and group B patients (n = 52) underwent implantation of a single (210° arc-length) Keraring segment according to the QN. Both treatments were combined with accelerated transepithelial cross-linking, and follow-up was 6 months. Main outcome measures were preoperative and postoperative visual acuity, subjective refraction and corneal topography.

Results: At postoperative month 6, group B exhibited statistically significantly higher values of mean uncorrected distance visual acuity (UDVA), sphere, K2, K-average, K-max and Q-anterior (p = 0.02, 0.01, 0.002, 0.001, 0.0001 and 0.03, respectively) compared to that of group A. However, group A exhibited better refractive cylindrical improvements (p = 0.04). In group A, we documented spontaneous extrusion of one Keraring segment.

Conclusion: Single 210° arc-length segment implantation using our objective QN was more efficacious for keratoconus treatment than using the subjective SN. The nomograms were comparable when the Q-anterior value was >-1.00; however, the QN was superior to the SN when the Q-anterior value was ≤-1.00. The QN yielded greater postoperative UDVA and smoother corneal remodelling than did the SN for treatment of grade 1 and 2 keratoconic eyes.

Keywords: Kerarings; Q-value nomogram; corneal asphericity; corneal cross-linking; intracorneal rings; keratoconus.

Publication types

  • Multicenter Study
  • Randomized Controlled Trial

MeSH terms

  • Adolescent
  • Adult
  • Cornea / diagnostic imaging
  • Cornea / surgery*
  • Corneal Topography / methods
  • Cross-Linking Reagents / therapeutic use*
  • Female
  • Follow-Up Studies
  • Humans
  • Keratoconus / diagnosis
  • Keratoconus / therapy*
  • Lens Implantation, Intraocular / methods*
  • Lenses, Intraocular / standards*
  • Male
  • Middle Aged
  • Nomograms*
  • Photochemotherapy / methods
  • Photosensitizing Agents / therapeutic use*
  • Prospective Studies
  • Prosthesis Design
  • Refraction, Ocular / physiology
  • Visual Acuity
  • Young Adult

Substances

  • Cross-Linking Reagents
  • Photosensitizing Agents