A retrospective analysis of usefulness of impulse oscillometry system in the treatment of asthma

Respir Res. 2020 Aug 31;21(1):226. doi: 10.1186/s12931-020-01494-x.

Abstract

Background: Bronchial asthma (BA) has different phenotypes, and it requires a clinically effective subtype classification system. The impulse oscillometry system (IOS) is an emerging technique device used in respiratory functional tests. However, its efficacy has not been validated. Therefore, this study aimed to assess the relationship between BA and the IOS parameters, and the difference in the therapeutic effects of inhaled corticosteroids (ICSs) among the subtype classifications was evaluated using the IOS.

Methods: Of the 245 patients with bronchial asthma who were screened, 108 were enrolled in this study. These patients were divided based on three subtypes according to the IOS result as follows: central predominant type (n = 34), peripheral predominant type (n = 58), and resistless type (n = 16). Then, the following ICSs were randomly prescribed in daily medical care: coarse-particle ICS (fluticasone propionate [FP]), fine-particle ICS (mometasone furoate [MF]), and moderate-particle ICS (budesonide [BUD]). The treatment effects were assessed using the Asthma Health Questionnaire (AHQ) and the Asthma Control Test (ACT) and were compared among the three subtypes.

Results: In the central predominant type, the AHQ score of the MF group was significantly higher than that of the FP group (15.4 vs. 3.6, p < 0.01) and the BUD group (15.4 vs. 8.8, p < 0.05); the ACT score of the FP group was significantly higher than that of the MF and BUD groups (24.3 vs. 21.7, 22.3, respectively, p < 0.05) at 4 weeks after treatment. In the peripheral predominant type, the AHQ score of the FP group was significantly higher than that of the MF group (14.1 vs. 3.4, p < 0.05); the ACT score of the FP group was lower than that of the MF and BUD groups (22.8 vs. 24.6, 24.4, respectively, p < 0.01) at 4 weeks after treatment.

Conclusions: An association was observed between IOS subtype classification and ICS particle size in terms of therapeutic efficacy in BA. This result indicates that the IOS could be an effective tool in the selection of ICS and the evaluation of the BA phenotype.

Keywords: Asthma control test; Asthma health questionnaire; Bronchial asthma; Impulse oscillometry system; Inhaled corticosteroids; Pulmonary function test.

Publication types

  • Observational Study

MeSH terms

  • Adult
  • Asthma / diagnosis*
  • Asthma / physiopathology
  • Asthma / therapy*
  • Female
  • Follow-Up Studies
  • Forced Expiratory Volume / physiology*
  • Humans
  • Male
  • Middle Aged
  • Oscillometry / methods*
  • Retrospective Studies
  • Treatment Outcome