Secondary Relining With Focal Flaring of Novel-Generation Balloon-Expandable Covered Stents for Endovascular Treatment of Significant Diameter Mismatch in the Aorto-Iliac Territory

Vascular. 2021 Apr;29(2):207-212. doi: 10.1177/1708538120945056. Epub 2020 Jul 29.

Abstract

Objectives: The aim of this study was to report on the safety and feasibility of secondary relining with focal flaring of novel-generation balloon-expandable covered stents for endovascular treatment of significant diameter mismatch in the aorto-iliac territory. Significant diameter mismatch was defined as >20% difference in the nominal diameter between the intended proximal and distal landing zones.

Methods: Patient A was an 84-year-old man with prior abdominal aortic aneurysm open repair with a straight 20 mm Dacron tube. He presented with a right common iliac artery aneurysm (Ø88 mm) with contained rupture. The Gore Viabahn endoprosthesis (9 mm × 5 cm) was inserted proximally about 15 mm above the occluded ostium of the internal iliac artery. Subsequently, the BeGraft Aortic® (16 mm × 48 mm) was inserted proximally up to the common iliac artery origin; its proximal portion was flared to 22 mm. Patient B was a 77-year-old man with prior endovascular abdominal aortic aneurysm repair with a Medtronic Endurant stent-graft. He presented with occlusion of the right limb of the aortic endoprosthesis and thrombosis that extended down to the level of the superficial femoral artery. After mechanical thrombectomy, two Gore Viabahn endoprosthesis (first one, 8 mm × 10 cm; second one, 10 mm × 15 cm) were inserted into the right iliac limb. Subsequently, the BeGraft Aortic® (12mm × 39mm) was inserted proximally up to the gate of the aortic stent-graft; its proximal portion was flared to 16 mm.

Results: Technical success and clinical success were achieved in both patients. Imaging follow-up (6 months for Patient A, 12 months for Patient B) showed correct placement of all stent-grafts without any graft-related adverse event. The patients remained free from new reinterventions or recurrent symptoms. Patient A died 8 months after the index procedure from acute respiratory failure after community acquired pneumonia.

Conclusion: Secondary relining with focal flaring of novel-generation balloon-expandable covered stents for endovascular treatment of significant diameter mismatch in the aorto-iliac territory is safe and feasible. Although mid-term results seem to be effective, longer follow-up is warranted to establish durability of the technique.

Keywords: Secondary intervention; aortoiliac disease; balloon-expandable covered stent; stent-graft.

Publication types

  • Case Reports

MeSH terms

  • Aged
  • Aged, 80 and over
  • Aneurysm, Ruptured / diagnostic imaging
  • Aneurysm, Ruptured / surgery*
  • Blood Vessel Prosthesis Implantation / adverse effects
  • Blood Vessel Prosthesis Implantation / instrumentation*
  • Blood Vessel Prosthesis*
  • Endovascular Procedures / adverse effects
  • Endovascular Procedures / instrumentation*
  • Fatal Outcome
  • Humans
  • Iliac Aneurysm / diagnostic imaging
  • Iliac Aneurysm / surgery*
  • Male
  • Prosthesis Design
  • Stents*
  • Treatment Outcome