Hybrid PET/MRI in non-small cell lung cancer (NSCLC) and lung nodules-a literature review

Eur J Nucl Med Mol Imaging. 2021 Feb;48(2):584-591. doi: 10.1007/s00259-020-04955-z. Epub 2020 Jul 27.

Abstract

Background: The use of hybrid PET/MRI for clinical staging is growing in several cancer forms and, consequently, PET/MRI has also gained interest in the assessment of non-small cell lung cancer (NSCLC) and lung lesions. However, lung evaluation with PET/MRI is associated with challenges related to technical issues and diagnostic image quality. We, therefore, investigated the published literature on PET/MRI for clinical staging in NSCLC or lung nodule detection specifically addressing diagnostic accuracy and technical issues.

Methods: The data originates from a systematic search performed in PubMed/MEDLINE, Embase, and Cochrane Library on hybrid PET/MRI in patients with cancer for a scoping review published earlier ( https://doi.org/10.1007/s00259-019-04402-8 ). Studies in English and German evaluating the diagnostic performance of hybrid PET/MRI for NSCLC or lung nodule detection in cancer patients were selected. Data reported in peer-reviewed journals without restrictions to year of publication were included.

Results: A total of 3138 publications were identified from which 116 published 2012-2018 were included. Of these, nine studies addressed PET/MRI in NSCLC (4) or lung nodule detection (5). Overall, PET/MRI did not provide advantages in preoperative T- and N-staging in NSCLC compared to PET/CT. The data on M-staging were too few for conclusions to be drawn. The lung nodule detection rate of PET/MRI was comparable to that of PET/CT for FDG-avid nodules larger than 10 mm, but the sensitivity of PET/MRI for detection of non-FDG-avid nodules smaller than 5 mm was low.

Conclusion: PET/MRI did not provide advantages in T- and N-staging of NSCLC compared to PET/CT. PET/MRI had a comparable sensitivity for detection of FDG-avid lung nodules and nodules over 10 mm, but PET/CT yielded a higher detection rate in non FDG-avid lung nodules under 5 mm. With PET/MRI, the overall detection rate for lung nodules in various cancer types remains inferior to that of PET/CT due to the lower diagnostic performance of MRI than CT in the lungs.

Keywords: 18F-FDG; Lung lesions; NSCLC; PET/CT; PET/MRI.

Publication types

  • Review

MeSH terms

  • Carcinoma, Non-Small-Cell Lung* / diagnostic imaging
  • Carcinoma, Non-Small-Cell Lung* / pathology
  • Fluorodeoxyglucose F18
  • Humans
  • Lung / pathology
  • Lung Neoplasms* / diagnostic imaging
  • Lung Neoplasms* / pathology
  • Magnetic Resonance Imaging
  • Neoplasm Staging
  • Positron Emission Tomography Computed Tomography
  • Positron-Emission Tomography
  • Sensitivity and Specificity
  • Tomography, X-Ray Computed

Substances

  • Fluorodeoxyglucose F18