Background/aim: Magnetic resonance (MR) and ultrasound (US) fusion imaging (MR-US fusion) is already used to guide prostate biopsies and has been proven accurate for diagnosing cervical cancer. In this study, we aimed to evaluate the feasibility and performance of MR-US fusion for characterizing adnexal masses.
Patients and methods: A retrospective study was conducted between 2014 and 2018 including women referred to our Gynaecological Oncology Department for characterization of an adnexal mass (n=106). Performance of MR-US fusion was evaluated in a subgroup of patients who underwent surgery (n=26). Two readers, blinded to final histology, performed and rated US findings according to the International Ovarian Tumor Analysis simple rules score, MR according to Ovarian-Adnexal Reporting Data System Magnetic score, and MR-US fusion through a tailored score. The reference outcome was the final pathology.
Results: MR-US fusion had a sensitivity of 100% (95%CI=80-100), specificity of 89% (95%CI=52-99), positive likelihood ratio of 9 (95%CI=1.4-57), and accuracy of 96% (95%CI=80-99).
Conclusion: MR-US fusion is feasible for characterizing adnexal masses to predict ovarian cancer.
Keywords: IOTA simple rules; MR-US fusion; Magnetic resonance; O-RADS MRI scoring system; adnexal masses; ovarian cancer; ultrasound.