3-D Intravascular Characterization of Blood Flow Velocity Fields with a Forward-Viewing 2-D Array

Ultrasound Med Biol. 2020 Sep;46(9):2560-2571. doi: 10.1016/j.ultrasmedbio.2020.05.022. Epub 2020 Jun 30.

Abstract

Risk stratification in coronary artery disease is an ongoing challenge for which few tools are available for quantifying physiology within coronary arteries. Recently, anatomy-driven computational fluid dynamic modeling has enabled the mapping of local flow dynamics in coronary stenoses, with derived parameters such as WSS exhibiting a strong capability for predicting adverse clinical events on a patient-specific basis. As cardiac catheterization is common in patients with coronary artery disease, minimally invasive technologies capable of identifying pathologic flow in situ in real time could have a significant impact on clinical decision- making. As a step toward in vivo quantification of slow flow near the arterial wall, proof-of-concept for 3-D intravascular imaging of blood flow dynamics is provided using a 118-element forward-viewing ring array transducer and a research ultrasound system. Blood flow velocity components are estimated in the direction of primary flow using an unfocused wave Doppler approach, and in the lateral and elevation directions, using a transverse oscillation approach. This intravascular 3-D vector velocity system is illustrated by acquiring real-time 3-D data sets in phantom experiments and in vivo in the femoral artery of a pig. The effect of the catheter on blood flow dynamics is also experimentally assessed in flow phantoms with both straight and stenotic vessels. Results indicate that 3-D flow dynamics can be measured using a small form factor device and that a hollow catheter design may provide minimal disturbance to flow measurements in a stenosis (peak velocity: 54.97 ± 2.13 cm/s without catheter vs. 51.37 ± 1.08 cm/s with hollow catheter, 6.5% error). In the future, such technologies could enable estimation of 3-D flow dynamics near the wall in patients already undergoing catheterization.

Keywords: 3-D ultrasound; Forward-viewing transducer; Intravascular ultrasound; Matrix array; Ring array; Transverse oscillation; Vector velocity.

Publication types

  • Research Support, N.I.H., Extramural
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Animals
  • Blood Flow Velocity*
  • Blood Vessels / diagnostic imaging*
  • Blood Vessels / physiology*
  • Constriction, Pathologic
  • Imaging, Three-Dimensional*
  • Phantoms, Imaging
  • Swine
  • Transducers
  • Ultrasonography, Interventional* / methods