This paper contains a vanadium redox flow battery stack with an electrode surface area 40 cm2 test data. The aim of the study was to characterize the performance of the stack of the original design. The dataset include three series of galvanostatic charge-discharge cycling in the potential region 8-16 V with current densities 75, 150 and 200 mA/cm2 for 100 cycles. Coulomb, voltaic, energy efficiencies and capacity utilization coefficient are also provided for all three series.
Keywords: Redox flow battery, stack, energy storage, vanadium, cyclic voltammetry, capacity utilization, efficiency, flow cell.