Responsiveness of the single item measure to detect change in physical activity

PLoS One. 2020 Jun 25;15(6):e0234420. doi: 10.1371/journal.pone.0234420. eCollection 2020.

Abstract

Objective: The objective of this study was to evaluate the responsiveness of the single item measure (SIM) to detect change in PA when compared to hip-worn accelerometry. A secondary aim was to provide further data on validity of the measure at a single time point.

Methods: Validity of the SIM to determine the number of days of ≥30 minutes of accelerometer-derived moderate-to-vigorous physical activity (MVPA) was assessed in 120 participants (78% female, 19% male, 3% other; age: 46 ± 11 years). Analysis of change was based on change in the number of days that participants completed ≥30 minutes of MVPA determined by the SIM and accelerometry over two 7-day periods in 90 participants (age: 47±11 years). Accelerometer data were analysed as total minutes of MVPA per day (MVPA-total) and as sustained bouts of 10 minutes or more of MVPA (MVPA-bouts). Validity of the SIM to detect change in MVPA, using accelerometer data as the reference measurement, was examined through Spearman's correlation and agreement in classification of change between SIM and accelerometry. Responsiveness to change was assessed by standardised response means and Cohen's d.

Results: Standardised response means for PA change were moderate for the SIM (0.77), MVPA-total (0.57) and MVPA-bouts (0.79). The correlation for change in number of days ≥30 minutes MVPA between the SIM and accelerometry were small to moderate (MVPA-total: r = 0.36 and MVP-bouts: r = 0.40). The SIM displayed moderate accuracy (60%-63%), using accelerometer data as the reference measurement, in detecting increases in days ≥30 minutes of MVPA.

Conclusion: The SIM is a potentially useful assessment tool for evaluating change in MVPA, particularly when device-based measures or longer self-report measures are not feasible.

Publication types

  • Evaluation Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Accelerometry / statistics & numerical data
  • Adult
  • Australia
  • Exercise / physiology*
  • Female
  • Humans
  • Male
  • Middle Aged
  • Reproducibility of Results
  • Self Report / statistics & numerical data
  • Surveys and Questionnaires / statistics & numerical data
  • Time Factors

Grants and funding

This research was supported by the Victorian Health Promotion Foundation (VicHealth), www.vichealth.vic.gov.au. One of the co-authors, AW, is a staff member of the funding body, and as such the funder had a role in the preparation of the manuscript. However, the funder had no role in the design of the study or the analysis of data.