Correlation between corneal demarcation line depth in epithelium-off and trans-epithelium accelerated corneal cross linking and keratoconus progression

Int J Ophthalmol. 2020 Jun 18;13(6):907-912. doi: 10.18240/ijo.2020.06.08. eCollection 2020.

Abstract

Aim: To compare corneal demarcation line (DL) depth in both accelerated epithelium-off and trans-epithelium cross linking (CXL) using anterior segment optical coherence tomography (AS-OCT) and its relation to maximum keratometry (Kmax) progression in both techniques.

Methods: A prospective comparative interventional study where patients with mild to moderate keratoconus (KC) were classified into two groups: accelerated epithelium-off and trans-epithelium CXL based on corneal pachymetry. Assessment of corneal DL depth was carried out after 3mo by AS-OCT. Kmax readings were evaluated after one year follow up using the Scheimpflug imaging system.

Results: Study included 74 eyes of 44 patients. Group A underwent epithelium-off CXL (41 eyes), while Group B underwent trans-epithelium CXL (33 eyes). At 3mo follow up, mean corneal DL depth in Group A was 219.9±58.4 µm while in Group B was 127.2±7.8 µm (P<0.05). The mean Kmax changed from 51.9±3.9 to 51.3±4.2 diopters in Group A and from 53.1±4.1 to 53.6±5 diopters in Group B with insignificant difference in Kmax changes in either group (P>0.05). In addition, no significant change in corneal pachymetry was found in both groups (mean change at 1y: 6.4±4.7 and -10.1±2.3 µm in Groups A and B respectively).

Conclusion: Despite a significantly deeper corneal DL depth created by accelerated epithelium-off CXL technique compared to accelerated trans-epithelium CXL, there is no significant impact on keratoconus progression.

Keywords: anterior segment optical coherence tomography; cross linking; demarcation line; keratoconus.