Tongue Part Movement Trajectories for /r/ Using Ultrasound

Perspect ASHA Spec Interest Groups. 2019 Dec;4(6):1644-1652. doi: 10.1044/2019_pers-19-00064.

Abstract

Purpose: Because it shows the movement of different parts of the tongue in real time, ultrasound biofeedback therapy is a promising technology for speech research and remediation. One limitation is the difficulty of interpreting real-time ultrasound images of tongue motion. Our image processing system, TonguePART, tracks the tongue surface and allows for the acquisition of quantitative tongue part trajectories.

Method: TonguePART automatically identifies the tongue contour based on ultrasound image brightness and tracks motion of the tongue root, dorsum, and blade in real time. We present tongue part trajectory data from 2 children with residual sound errors on /r/ and 2 children with typical speech, focusing on /r/ (International Phonetic Alphabet ɹ) in the phonetic context /ɑr/. We compared the tongue trajectories to magnetic resonance images of sustained vowel /ɑ/ and /r/.

Results: Measured trajectories show larger overall displacement and greater differentiation of tongue part movements for children with typical speech during the production of /ɑr/, compared to children with residual speech sound disorders.

Conclusion: TonguePART is a fast, reliable method of tracking articulatory movement of tongue parts for syllables such as /ɑr/. It is extensible to other sounds and phonetic contexts. By tracking tongue parts, clinical researchers can investigate lingual coordination. TonguePART is suitable for real-time data collection and biofeedback. Ultrasound biofeedback therapy users may make more progress using simplified biofeedback of tongue movement.