An improved recombinase polymerase amplification assay for visual detection of Vibrio parahaemolyticus with lateral flow strips

J Food Sci. 2020 Jun;85(6):1834-1844. doi: 10.1111/1750-3841.15105. Epub 2020 May 25.

Abstract

Vibrio parahaemolyticus is an important pathogenic bacterium in both food safety management and mariculture. Rapid and accurate detection technologies are critical for effective control of its outbreak and spreading. Conventional technologies and polymerase chain reaction (PCR)-based approaches have limited usage because of the requirement of laboratory instruments and trained personnel. Using the isothermal recombinase polymerase amplification (RPA) technology, several detection assays have been developed with added convenience. Combining the lateral flow strip (LFS) test with RPA can further simplify the detection. In this study, an improved RPA assay using LFS for visual detection of V. parahaemolyticus was developed. Primers were designed targeting the virulence genes and screened for amplification efficiency, nonspecific amplification, and primer-dimer formation. Probes were designed for the best primer pairs, and the weakness of LFS tests, being easily affected by primer-dependent artifacts, was overcome by sequence modifications on primers and probe. The RPA-LFS assay took 25 min at 35 to 45 °C, and showed excellent specificity. It detected as low as one colony forming unit (CFU) of V. parahaemolyticus per reaction without DNA purification, or 10 CFU/10 g spiked food samples with 2 hr of enrichment. The detection limit was better than the currently available RPA-based detection methods. Application of the RPA-LFS assay for simulated samples or real clinical samples showed accurate and consistent detection results compared to bioassay and quantitative PCR. The RPA-LFS assay provided a rapid, accurate, and convenient V. parahaemolyticus detection method suitable for on-site detection in resource-limited conditions. PRACTICAL APPLICATION: This research developed a rapid and visual detection technology for Vibrio parahaemolyticus that is not dependent on complicated equipment. The detection process takes 25 min and the result is read with the naked eye. A detection kit can be developed based on this technology for on-site detection of V. parahaemolyticus in resource-limited regions for food safety management and mariculture.

Keywords: Vibrio parahaemolyticus; false positive; isothermal amplification; lateral flow strip; rapid detection; recombinase polymerase amplification.

Publication types

  • Evaluation Study

MeSH terms

  • DNA Primers / genetics
  • DNA, Bacterial / genetics
  • Food Contamination / analysis
  • Food Microbiology / methods*
  • Limit of Detection
  • Polymerase Chain Reaction / methods*
  • Sensitivity and Specificity
  • Vibrio parahaemolyticus / genetics
  • Vibrio parahaemolyticus / growth & development
  • Vibrio parahaemolyticus / isolation & purification*

Substances

  • DNA Primers
  • DNA, Bacterial