Finite element analysis of dual small plate fixation and single plate fixation for treatment of midshaft clavicle fractures

J Orthop Surg Res. 2020 Apr 15;15(1):148. doi: 10.1186/s13018-020-01666-x.

Abstract

Background: Midshaft clavicle fractures are one of the most familiar fractures. And, dual small plate fixation has been reported as can minimize hardware-related complications. However, the biomechanical properties of the dual small plate fixation have not yet been thoroughly evaluated. Here, we report the results of a finite element analysis of the biomechanical properties of midshaft clavicle fractures treated with dual small plating and superior and anteroinferior single plate fixation.

Methods: A three-dimensional (3D) finite element model of the midshaft clavicle fractures was created, whose 4-mm transverse fracture gap, having an angle < 30 degree and devoid of overlapping triangles, was simulated between the fractured segments of the middle-shaft of the clavicle. The equivalent von Mises stress and displacement of the model was used as the output measures for analysis.

Results: No significant differences were found between dual plating, superior or anteroinferior single plating in cantilever bending, axial compression, and axial torsion. Dual plating with a smaller plate-screw construct is biomechanically eligible to compare with superior and anteroinferior single plate fixation using larger plate-screw constructs.

Conclusions: This study demonstrated that larger plate-screw constructs for the treatment of simple are placed clavicular fractures; however, weight-bearing and exorbitant shoulder activity should be avoided after the operation. Therefore, dual plating may provide a viable option for fixing midshaft clavicle fractures and, thus, may be preferred for patients who need early activity.

Keywords: Biomechanics; Clavicle fracture; Dual small plating; Finite element analysis; Larger single plate constructs.

MeSH terms

  • Biomechanical Phenomena / physiology
  • Bone Plates*
  • Clavicle / diagnostic imaging
  • Clavicle / injuries
  • Clavicle / surgery*
  • Finite Element Analysis*
  • Fracture Fixation, Internal / methods*
  • Fractures, Bone / diagnostic imaging
  • Fractures, Bone / surgery*
  • Humans
  • Imaging, Three-Dimensional / methods*
  • Male
  • Middle Aged
  • Treatment Outcome