The use of pulse-echo ultrasound in women with a recent non-vertebral fracture to identify those without osteoporosis and/or a subclinical vertebral fracture: a pilot study

Arch Osteoporos. 2020 Apr 14;15(1):56. doi: 10.1007/s11657-020-00730-7.

Abstract

A pilot study on the use of P-EU to identify patients without osteoporosis and/or a subclinical vertebral fracture after a recently sustained non-vertebral fracture (NVF).

Introduction: Screening with portable devices at emergency departments or plaster rooms could be of interest to limit referrals for dual X-ray absorptiometry (DXA) and vertebral fracture assessment (VFA). We calculated the number of negative tests for osteoporosis and/or subclinical vertebral fractures (VFs) using pulse-echo ultrasonometry (P-UE) at different thresholds.

Patients and methods: In this cross-sectional study, 209 consecutive women of 50-70 years with a recent non-vertebral fracture (NVF) were studied at the Fracture Liaison Service (FLS) of one hospital. All women received DXA/VFA and P-EU (Bindex®) assessments. Various P-EU thresholds (based on the density index (DI, g/cm2)) were analyzed to calculate the best balance between true negative (indeed no osteoporosis and/or subclinical VF) and false negative tests (osteoporosis and/or subclinical VF according to DXA/VFA).

Results: Eighty-three women had osteoporosis (40%) and 17 women at least one VF (8%). Applying the manufacturer's recommended P-EU threshold (DI 0.844 g/cm2) being their proposed cut-off for not having hip osteoporosis resulted in 77 negative tests (37%, 31% true negative and 6% false negative tests). A DI of 0.896 g/cm2 resulted in 40 negative tests (19.3%) (38 true negative (18.3%) and 2 false negative tests (1.0%)).

Conclusion: The application of P-EU enables the identification of a substantial proportion of women with recent non-vertebral fractures at the FLS who would not need a DXA/VFA referral because they had no osteoporosis and/or subclinical vertebral fractures. The most conservative P-EU threshold resulted in 18.3% true negative tests verified by DXA/VFA against 1% false negative test results.

Keywords: DXA/VFA; FLS; Non-vertebral fracture; Osteoporosis; Pulse-echo ultrasound; Subclinical vertebral fracture.

Publication types

  • Evaluation Study

MeSH terms

  • Aged
  • Bone Density
  • Cross-Sectional Studies
  • Diagnosis, Differential
  • False Negative Reactions
  • Female
  • Fractures, Bone / complications
  • Humans
  • Mass Screening / methods*
  • Middle Aged
  • Osteoporosis / complications
  • Osteoporosis / diagnostic imaging*
  • Pilot Projects
  • Point-of-Care Testing
  • Reference Values
  • Referral and Consultation / statistics & numerical data*
  • Spinal Fractures / diagnostic imaging*
  • Spinal Fractures / etiology
  • Ultrasonography / methods
  • Ultrasonography / statistics & numerical data*