COMPLIANCE TESTING FOR HUMAN BODY MODEL EXPOSURE TO ELECTROMAGNETIC FIELDS FROM A HIGH-POWER WIRELESS CHARGING SYSTEM FOR DRONES

Radiat Prot Dosimetry. 2020 Jul 7;189(1):13-27. doi: 10.1093/rpd/ncaa008.

Abstract

Recently, a wireless charging system (WCS) for drones has been extensively studied, although standards for compliance testing of a WCS for drones have yet to be established. In this study, we propose methods for human exposure assessments of a WCS for drones by comprehensively considering the various positions of the system and the postures of human body models. The electromagnetic fields from a WCS are modeled and the internal quantities of the human body models, consisting of current density, internal electric field and specific absorption rate, are calculated. The incident fields around the WCS and the internal quantities are analyzed at 140 kHz, which is the operating frequency of the WCS applied. Results of an exposure assessment based on the confirmed worst-case scenario are presented. In addition, the internal quantities depending on the human body models and the material characteristics of the simplified models are also discussed using four different anatomical and simplified human body models.

MeSH terms

  • Electricity
  • Electromagnetic Fields*
  • Human Body*
  • Humans
  • Posture