Method development and validation of dissolution testing for nicotine release from smokeless tobacco products using flow-through cell apparatus and UPLC-PDA

J Chromatogr B Analyt Technol Biomed Life Sci. 2020 Mar 15:1141:122012. doi: 10.1016/j.jchromb.2020.122012. Epub 2020 Feb 4.

Abstract

Developing dissolution testing methods to measure the nicotine release profiles from smokeless tobacco products is valuable for product assessment and product-to-product comparisons. In this work, we developed a robust dissolution method to study the in vitro release of nicotine from smokeless tobacco products using the U.S. Pharmacopeia flow-through cell dissolution apparatus 4 (USP-4). We further developed and validated a sensitive Ultra Performance Liquid Chromatography coupled to Photodiode Array detector (UPLC-PDA) method for the accurate quantitation of the released nicotine into artificial saliva, which is our selected dissolution medium. We have successfully shown the applicability of the validated method by investigating the release profiles of nicotine from various commercial and CORESTA reference smokeless tobacco products [CRP 1.1 (Swedish-style snus pouch), CRP 2.1 (American-style loose moist snuff), CRP 4 (loose-leaf chewing tobacco) and CRP 4.1 (chopped loose-leaf chewing tobacco)]. Nicotine release profiles were analyzed by calculating the difference factor (f1) and similarity factor (f2) by adopting a methodology referenced in the Guidance for Industry from FDA's Center for Drug Evaluation and Research (CDER) and by fitting the release profile curves using a first order kinetic model. Nicotine release was found to be dependent on the form and cut of the smokeless tobacco products, with a slower release observed for snus and loose-leaf, compared to chopped and loose moist snuff smokeless tobacco. This dissolution methodology can be extended to measure and compare release of other constituents from smokeless tobacco products and has the potential for method standardization.

Keywords: CORESTA; Dissolution; Method development; Nicotine; Nicotine performance test; Release profile; Smokeless tobacco; UPLC-PDA; Validation.

MeSH terms

  • Chemistry Techniques, Analytical / instrumentation
  • Chemistry Techniques, Analytical / methods
  • Chromatography, High Pressure Liquid / methods*
  • Equipment Design
  • Humans
  • Limit of Detection
  • Linear Models
  • Models, Biological
  • Nicotine / analysis*
  • Nicotine / pharmacokinetics
  • Reproducibility of Results
  • Saliva / chemistry
  • Tobacco, Smokeless / analysis*

Substances

  • Nicotine