Exploring the value of the double source CT angiography in diagnosing in-stent restenosis in lower limb artery

Vascular. 2020 Jun;28(3):267-273. doi: 10.1177/1708538119899317. Epub 2020 Jan 10.

Abstract

Objectives: This paper is aimed to explore the value of double source CT angiography (DS-CTA) for diagnosing in-stent restenosis in lower limb artery.

Methods: From January 2016 to October 2018, all patients with stent in lower limb artery in our hospital were investigated by both DS-CTA and digital subtraction angiography. We measured the minimum lumen diameter and the diameter of the proximal normal vessels under each stent placement. The in-stent restenosis is defined as restenosis when the lumen area decreased by more than 50%. Digital subtraction angiography was performed within 1 week after DS-CT scan. Relationship between DS-CTA and digital subtraction angiography for diagnosing in-stent restenosis in lower limb artery was analyzed. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of DS-CTA for diagnosis of in-stent restenosis were analyzed with digital subtraction angiography as the reference standard. A total of 68 stents were placed in 51 patients. Among these patients, 27 cases were diagnosed as in-stent restenosis, presenting as endovascular contrast agent bias or crescent filling defect with the lumen area reducing over 50%, 6 cases of which had no significant in-stent restenosis by digital subtraction angiography analysis. Furthermore, 12 cases were occlusion, in which there was no high density contrast agent in stents; the remaining 41 stents were unobstructed and the contrast agent was filled well, 8 cases of which had significant in-stent restenosis by digital subtraction angiography analysis. In addition, four stents were deformed or distorted. Statistical analysis demonstrated the concentrations of DS-CTA and digital subtraction angiography in diagnosing in-stent restenosis for lower limb artery were closely related, and the sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of DS-CTA were 72.4%, 84.6%, 77.8%, 80.5%, and 79.4%, respectively.

Conclusion: DS-CTA has a potential reliability for diagnosis of in-stent restenosis in lower limb artery, which may be further improved to be used for clinical interventional treatment of vascular diseases.

Keywords: Double source CT angiography; in-stent restenosis; lower limb artery.

Publication types

  • Comparative Study

MeSH terms

  • Adult
  • Aged
  • Aged, 80 and over
  • Angiography, Digital Subtraction*
  • Computed Tomography Angiography*
  • Endovascular Procedures / adverse effects
  • Endovascular Procedures / instrumentation*
  • Female
  • Humans
  • Lower Extremity / blood supply*
  • Male
  • Middle Aged
  • Peripheral Arterial Disease / diagnostic imaging
  • Peripheral Arterial Disease / physiopathology
  • Peripheral Arterial Disease / therapy*
  • Predictive Value of Tests
  • Reproducibility of Results
  • Stents*
  • Treatment Outcome